Literature DB >> 21782289

[Utility of the dead space fraction (Vd/Vt) as a predictor of extubation success].

A González-Castro1, V Suárez-Lopez, V Gómez-Marcos, C González-Fernandez, D Iglesias-Posadilla, J Burón-Mediavilla, J C Rodríguez-Borregan, E Miñambres, J Llorca.   

Abstract

PURPOSE: To determine the value of Vd/Vt as a predictor of extubation failure in patients with mechanical ventilation admitted to the intensive care units.
DESIGN: A prospective, observational cohort study conducted from 1 September 2010 to 1 March 2011.
SETTING: General intensive care unit (G-ICU) of a third level university hospital. PATIENTS OR PARTICIPANTS: The study included patients on mechanical ventilation (MV) for over 12 hours, and who in the process of weaning were subjected to low-level pressure support. Exclusion criteria were age under 18 years, ventilation via tracheotomy and patients failing to cooperate for different reasons. During the study, 392 patients were admitted to the G-ICU; of these, 214 required MV. The weaning process was started in 154 cases. Fifty-four patients were excluded from the study, and 24 were not extubated from MV. A total of 76 patients were finally extubated and analyzed. VARIABLES OF INTEREST: Vd/Vt was calculated as the ratio (PaCO(2)-Pє CO(2))/PaCO(2), with the recorded parameters.
RESULTS: Logistic regression analysis showed a significant association between the Vd/Vt and extubation failure, with OR=1.52 (95%CI 1.11 to 2.09, p=0.008). The area under the ROC curve with respect to the prediction of extubation failure according to the Vd/Vt value was 0.94 (95%CI 0.86 to 0.98, p<0.0001).
CONCLUSIONS: Vd/Vt is a powerful predictor of extubation failure in patients on MV.
Copyright © 2011 Elsevier España, S.L. y SEMICYUC. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21782289     DOI: 10.1016/j.medin.2011.05.016

Source DB:  PubMed          Journal:  Med Intensiva        ISSN: 0210-5691            Impact factor:   2.491


  7 in total

Review 1.  Using the features of the time and volumetric capnogram for classification and prediction.

Authors:  Michael B Jaffe
Journal:  J Clin Monit Comput       Date:  2016-01-18       Impact factor: 2.502

2.  The relationship between ventilatory ratio (VR) and 28-day hospital mortality by restricted cubic splines (RCS) in 14,328 mechanically ventilated ICU patients.

Authors:  Yingying Yang; Yi Chi; Siyi Yuan; Qing Zhang; Longxiang Su; Yun Long; Huaiwu He
Journal:  BMC Pulm Med       Date:  2022-06-13       Impact factor: 3.320

3.  Resting Dead Space Fraction as Related to Clinical Characteristics, Lung Function, and Gas Exchange in Male Patients with Chronic Obstructive Pulmonary Disease.

Authors:  Ming-Lung Chuang; Benjamin Yung-Thing Hsieh; I-Feng Lin
Journal:  Int J Gen Med       Date:  2021-02-03

4.  Physiologic Analysis and Clinical Performance of the Ventilatory Ratio in Acute Respiratory Distress Syndrome.

Authors:  Pratik Sinha; Carolyn S Calfee; Jeremy R Beitler; Neil Soni; Kelly Ho; Michael A Matthay; Richard H Kallet
Journal:  Am J Respir Crit Care Med       Date:  2019-02-01       Impact factor: 30.528

5.  Effects of neurally adjusted ventilatory assist on air distribution and dead space in patients with acute exacerbation of chronic obstructive pulmonary disease.

Authors:  Qin Sun; Ling Liu; Chun Pan; Zhanqi Zhao; Jingyuan Xu; Airan Liu; Haibo Qiu
Journal:  Crit Care       Date:  2017-06-02       Impact factor: 9.097

6.  Can Transcutaneous CO2 Tension Be Used to Calculate Ventilatory Dead Space? A Pilot Study.

Authors:  Pradeep H Lakshminarayana; Adiba A Geeti; Umer M Darr; David A Kaufman
Journal:  Crit Care Res Pract       Date:  2016-09-05

Review 7.  Volumetric capnography: lessons from the past and current clinical applications.

Authors:  Sara Verscheure; Paul B Massion; Franck Verschuren; Pierre Damas; Sheldon Magder
Journal:  Crit Care       Date:  2016-06-23       Impact factor: 9.097

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.