Literature DB >> 21781934

Streptomyces anulatus from indoor air of moldy houses induce NO and IL-6 production in a human alveolar epithelial cell-line.

J Jussila1, M Ruotsalainen, H Komulainen, K Savolainen, A Nevalainen, M R Hirvonen.   

Abstract

Moisture associated microbial growth in buildings may cause respiratory symptoms such as pulmonary inflammation. We studied the effects of spores of Streptomyces anulatus, commonly found in moldy buildings, on the production of nitric oxide (NO), interleukin-6 (IL-6), interleukin-5 (IL-5), interleukin-4 (IL-4), and tumour necrosis factor alpha (TNFα), as well as cell viability in human alveolar II type epithelial cell line (A549). Cells were exposed in vitro to S. anulatus spores with and without interferon-γ (IFNγ) in vitro. Lipopolysaccharide (LPS) was used as a reference substance. S. anulatus alone, and in combination with IFNγ induced NO and IL-6 production and decreased cell viability whereas IL-4, IL-5 or TNFα production were not affected. IFNγ alone had a weaker but otherwise similar effect as S. anulatus on NO and IL-6 production and it potentiated the effects of S. anulatus. LPS did not induce NO or cytokine production, or affect cell viability in A549 cells. These data indicate that spores of S. anulatus induce the excretion of inflammatory mediators in respiratory epithelial cells, which may partly explain the adverse respiratory health effects experienced by individuals exposed to the indoor air of moldy houses.

Entities:  

Year:  1999        PMID: 21781934     DOI: 10.1016/s1382-6689(99)00022-8

Source DB:  PubMed          Journal:  Environ Toxicol Pharmacol        ISSN: 1382-6689            Impact factor:   4.860


  3 in total

1.  Streptomycetes in house dust: associations with housing characteristics and endotoxin.

Authors:  E Johansson; S Vesper; L Levin; G LeMasters; S Grinshpun; T Reponen
Journal:  Indoor Air       Date:  2011-03-14       Impact factor: 5.770

2.  Association of Streptomyces community composition determined by PCR-denaturing gradient gel electrophoresis with indoor mold status.

Authors:  Elisabet Johansson; Tiina Reponen; Jarek Meller; Stephen Vesper; Jagjit Yadav
Journal:  Environ Monit Assess       Date:  2014-10-22       Impact factor: 2.513

3.  Stenotrophomonas, Mycobacterium, and Streptomyces in home dust and air: associations with moldiness and other home/family characteristics.

Authors:  E Kettleson; S Kumar; T Reponen; S Vesper; D Méheust; S A Grinshpun; A Adhikari
Journal:  Indoor Air       Date:  2013-03-19       Impact factor: 5.770

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.