Literature DB >> 21781418

Comparison of a rapid commercial test, Enterocheck WB(®), with automated blood culture for diagnosis of typhoid fever.

R Anusha1, R Ganesh, J Lalitha.   

Abstract

BACKGROUND: Rapid diagnosis of typhoid fever is very important in the timely initiation of therapy.
OBJECTIVES: To evaluate the sensitivity and specificity of the Enterocheck WB(®) test.
METHODS: In a prospective study, the sensitivity and specificity of Enterocheck WB(®) that detects IgM antibodies to Salmonella typhi were compared with blood culture using BacT/Alert.
RESULTS: Four hundred and fifty patients with suspected typhoid fever were assessed both by blood culture and Enterocheck WB(®); 100 of them were either Enterocheck WB(®)-positive or blood culture-positive or both for S. typhi. Both tests were positive in 47 of the 100 patients. In 45 patients, Enterocheck WB(®) was positive but blood culture was negative. In eight cases, Enterocheck was negative but blood culture was positive. Using blood culture as the gold standard, the sensitivity of Enterocheck WB(®) was 85.5%, specificity 88.6%, negative predictive value 97.7% and positive predictive value 51.1%.
CONCLUSION: The Enterocheck WB(®) test can be performed at the bedside in 15 minutes and is a useful rapid method for diagnosis of typhoid fever.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21781418     DOI: 10.1179/1465328111Y.0000000030

Source DB:  PubMed          Journal:  Ann Trop Paediatr        ISSN: 0272-4936


  5 in total

Review 1.  Rapid diagnostic tests for typhoid and paratyphoid (enteric) fever.

Authors:  Lalith Wijedoru; Sue Mallett; Christopher M Parry
Journal:  Cochrane Database Syst Rev       Date:  2017-05-26

2.  Clinical Profile and the Role of Rapid Serological Tests: Typhifast IgM and Enterocheck WB in the Diagnosis of Typhoid Fever.

Authors:  Rahul J Bhume; Prakash Babaliche
Journal:  Indian J Crit Care Med       Date:  2020-05

Review 3.  A systematic review and meta-analysis of the performance of two point of care typhoid fever tests, Tubex TF and Typhidot, in endemic countries.

Authors:  Kamala Thriemer; Benedikt Ley; Joris Menten; Jan Jacobs; Jef van den Ende
Journal:  PLoS One       Date:  2013-12-16       Impact factor: 3.240

4.  Comparative accuracy of typhoid diagnostic tools: A Bayesian latent-class network analysis.

Authors:  Paul Arora; Kristian Thorlund; Darren R Brenner; Jason R Andrews
Journal:  PLoS Negl Trop Dis       Date:  2019-05-08

5.  A Meta-Analysis of Typhoid Diagnostic Accuracy Studies: A Recommendation to Adopt a Standardized Composite Reference.

Authors:  Helen L Storey; Ying Huang; Chris Crudder; Allison Golden; Tala de los Santos; Kenneth Hawkins
Journal:  PLoS One       Date:  2015-11-13       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.