Literature DB >> 21777797

Comparing homatropine and atropine in pediatric cycloplegic refractions.

Bhavin M Shah1, Pradeep Sharma, Vimla Menon, Rohit Saxena, Jai Pal Singh.   

Abstract

PURPOSE: To compare cycloplegic efficacy of homatropine and atropine in pediatric refractions and derive a regression formula to calculate refraction findings for both agents.
METHODS: Children between the ages of 4 to 10 years with refractive error underwent cycloplegic refraction with 2% homatropine and 1% atropine by retinoscopy and automated refraction. Refractive data were compared by the use of power vector analysis. Primary outcome measures were spherical equivalent (SE), astigmatic components of refractive error (J(0) and J(45)), overall blur strength of refractive error, and residual accommodation.
RESULTS: A total of 63 children with refractive error were enrolled (mean age, 6.7 ± 1.6 years). Compared with homatropine, atropine uncovered significantly greater hyperopic SE in patients with hypermetropia (4.2 ± 2.5 D [atropine] vs 3.5 ± 2.3 D [homatropine]; P < 0.001) as well as myopia (-1.8 ± 1.4 D [atropine] vs -2.1 ± 1.4 D [homatropine]; P < 0.001). Overall blur strength was significantly greater with atropine (3.1 ± 2.1 [atropine] vs 2.9 ± 1.9 [homatropine]; P = 0.003). Homatropine had a significantly greater residual accommodation (1.8 ± 0.4 D [atropine] vs 3.1 ± 0.5 D [homatropine]; P < 0.001). A regression formula was derived.
CONCLUSIONS: Of the 2 cycloplegic agents, atropine yielded more consistent results than homatropine; however atropine had a relatively slow onset and prolonged effect. Our regression formula may make it possible to derive atropine-like results while using the clinically more versatile homatropine.
Copyright © 2011 American Association for Pediatric Ophthalmology and Strabismus. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21777797     DOI: 10.1016/j.jaapos.2010.12.020

Source DB:  PubMed          Journal:  J AAPOS        ISSN: 1091-8531            Impact factor:   1.220


  3 in total

1.  Efficacy and safety of acupuncture for patients with pseudomyopia: A protocol for systematic review and meta-analysis.

Authors:  Ye Niu; Wei Zheng; Shan Wang; Qi Zhao; Lijuan Wei; Yang Zhao; Bo Wang; Yuan Ju; Fuchun Wang
Journal:  Medicine (Baltimore)       Date:  2022-02-11       Impact factor: 1.817

2.  Comparison of the Near Eye Tool for Refractive Assessment (NETRA) and non-cycloplegic subjective refraction.

Authors:  Nabeela Hasrod; Alan Rubin
Journal:  BMJ Open Ophthalmol       Date:  2022-04-01

3.  National consensus statement regarding pediatric eye examination, refraction, and amblyopia management.

Authors:  Rohit Saxena; Pradeep Sharma
Journal:  Indian J Ophthalmol       Date:  2020-02       Impact factor: 1.848

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.