Literature DB >> 21777099

Bond strength of newer dentin bonding agents in different clinical situations.

Mithra N Hegde1, Jyothi Manjunath.   

Abstract

This study compared the tensile bond strengths of different adhesive systems to different dentinal substrate conditions. The adhesive systems used were Adper Single Bond 2 total etch, XP Bond total etch, and two all-in-one adhesives, Adper Easy One and Xeno V. Ninety-six intact human premolars extracted on periodontal or orthodontic grounds were collected and stored in 0.9% physiologic saline for less than four weeks. Teeth were carefully cleaned to remove the soft tissue remnants. The occlusal surfaces were ground until the level of the dentinoenamel junction, exposing superficial dentin using a low-speed diamond disc. A standard smear layer was produced by wet sanding the dentin surface with 600-grit silicon carbide sandpaper for 40 seconds. The 96 specimens were embedded in autopolymerizing acrylic resin and divided into four groups of 24 each based on the dentin bonding agents used. Each group consisted of 24 specimens, which were further divided into two subgroups of 12 specimens each, moist dentin and dentin air-dried for 10 seconds. The regions of interest for adhesion were demarcated in each sample using adhesive tape, with a 4-mm–diameter hole isolating the peripheral region, and each adhesive system was employed. Four adhesive systems, two total etch and two self-etching adhesive, were applied to different dentinal substrates as per the manufacturers' instructions. Following the adhesive application, the specimens were restored with composite material using a metallic mold measuring 5 mm in diameter and 5 mm in height to keep the material in cylindrical form and were light cured per manufacturers' instructions. After being stored for 24 hours in distilled water at room temperature, the specimens were thermocycled for 550 cycles at temperatures ranging from 5°C to 60°C with a dwell time of 15 seconds in each bath and a transfer time of five seconds. The tensile bond strengths were determined using a Universal loading machine (Lloyd Universal Testing Machine) at a cross-head speed of 1 mm/min. On moist dentin, total-etch adhesives showed higher bond strength than did the all-in-one adhesives. Under the dry dentin condition, XP Bond exhibited significantly higher bond strength than did the Adper Single Bond 2 and two all-in-one adhesives, Adper Easy One and Xeno V.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21777099     DOI: 10.2341/10-55-L

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  5 in total

1.  Catechol-Functionalized Synthetic Polymer as a Dental Adhesive to Contaminated Dentin Surface for a Composite Restoration.

Authors:  Sang-Bae Lee; Carlos González-Cabezas; Kwang-Mahn Kim; Kyoung-Nam Kim; Kenichi Kuroda
Journal:  Biomacromolecules       Date:  2015-07-31       Impact factor: 6.988

2.  Influence of salivary contamination on the dentin bond strength of two different seventh generation adhesive systems: In vitro study.

Authors:  Taranjeet Kaur Bhatia; Hemant Asrani; Harpreet Banga; Aditi Jain; Sudhir S Rawlani
Journal:  J Conserv Dent       Date:  2015 Nov-Dec

3.  Effect of oxalic acid pre-treatment in restorations of non-carious cervical lesions: A randomized clinical trial.

Authors:  André Mattos Brito de Souza; Regina Claudia Ramos Colares; Juliano Satori Mendonça; Lidiany Karla Azevedo Rodrigues; Sérgio Lima Santiago
Journal:  J Conserv Dent       Date:  2014-09

4.  Comparative study of different cytotoxicity of bonding systems with different dentin thickness on L929 cell line: An experimental study.

Authors:  Ehsan Baradaran Nasseri; Ali Eskandarizadeh
Journal:  Dent Res J (Isfahan)       Date:  2020-12-10

5.  Comparative evaluation of clinical performance of two self-etch adhesive systems with total-etch adhesive system in noncarious cervical lesions: An in vivo study.

Authors:  Vasanta Ramesh Digole; Manjusha M Warhadpande; Parag Dua; Darshan Dakshindas
Journal:  J Conserv Dent       Date:  2020-11-05
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.