Abstract

PURPOSE: Three-dimensional ultrasound (3D US) of the carotid artery provides measurements of arterial wall and plaque [vessel wall volume (VWV)] that are complementary to the one-dimensional measurement of the carotid artery intima-media thickness. 3D US VWV requires an observer to delineate the media-adventitia boundary (MAB) and lumen-intima boundary (LIB) of the carotid artery. The main purpose of this work was to develop and evaluate a semiautomated segmentation algorithm for delineating the MAB and LIB of the carotid artery from 3D US images.
METHODS: To segment the MAB and LIB, the authors used a level set method and combined several low-level image cues with high-level domain knowledge and limited user interaction. First, the operator initialized the algorithm by choosing anchor points on the boundaries, identified in the images. The MAB was segmented using local region- and edge-based energies and an energy that encourages the boundary to pass through anchor points from the preprocessed images. For the LIB segmentation, the authors used local and global region-based energies, the anchor point-based energy, as well as a constraint promoting a boundary separation between the MAB and LIB. The data set consisted of 231 2D images (11 2D images per each of 21 subjects) extracted from 3D US images. The image slices were segmented five times each by a single observer using the algorithm and the manual method. Volume-based, region-based, and boundary distance-based metrics were used to evaluate accuracy. Moreover, repeated measures analysis was used to evaluate precision.
RESULTS: The algorithm yielded an absolute VWV difference of 5.0% +/- 4.3% with a segmentation bias of -0.9% +/- 6.6%. For the MAB and LIB segmentations, the method gave absolute volume differences of 2.5% +/- 1.8% and 5.6% +/- 3.0%, Dice coefficients of 95.4% +/- 1.6% and 93.1% +/- 3.1%, mean absolute distances of 0.2 +/- 0.1 and 0.2 +/- 0.1 mm, and maximum absolute distances of 0.6 +/- 0.3 and 0.7 +/- 0.6 mm, respectively. The coefficients of variation of the algorithm (5.1%) and manual methods (3.9%) were not significantly different, but the average time saved using the algorithm (2.8 min versus 8.3 min) was substantial.
CONCLUSIONS: The authors generated and tested a semiautomated carotid artery VWV measurement tool to provide measurements with reduced operator time and interaction, with high Dice coefficients, and with necessary required precision.

Entities:  

Mesh:

Year:  2011        PMID: 21776783     DOI: 10.1118/1.3574887

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  3D ultrasound centerline tracking of abdominal vessels for endovascular navigation.

Authors:  L Zhang; S Parrini; C Freschi; V Ferrari; S Condino; M Ferrari; D Caramella
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-07-05       Impact factor: 2.924

2.  Three-dimensional ultrasound measurements of carotid vessel wall and plaque thickness and their relationship with pulmonary abnormalities in ex-smokers without airflow limitation.

Authors:  Jieyu Cheng; Damien Pike; Tommy W S Chow; Miranda Kirby; Grace Parraga; Bernard Chiu
Journal:  Int J Cardiovasc Imaging       Date:  2016-06-24       Impact factor: 2.357

3.  Deep learning-based carotid media-adventitia and lumen-intima boundary segmentation from three-dimensional ultrasound images.

Authors:  Ran Zhou; Aaron Fenster; Yujiao Xia; J David Spence; Mingyue Ding
Journal:  Med Phys       Date:  2019-06-11       Impact factor: 4.071

4.  Ultrasound common carotid artery segmentation based on active shape model.

Authors:  Xin Yang; Jiaoying Jin; Mengling Xu; Huihui Wu; Wanji He; Ming Yuchi; Mingyue Ding
Journal:  Comput Math Methods Med       Date:  2013-03-06       Impact factor: 2.238

5.  One, two and three-dimensional ultrasound measurements of carotid atherosclerosis before and after cardiac rehabilitation: preliminary results of a randomized controlled trial.

Authors:  Tamas J Lindenmaier; Daniel N Buchanan; Damien Pike; Tim Hartley; Robert D Reid; J David Spence; Richard Chan; Michael Sharma; Peter L Prior; Neville Suskin; Grace Parraga
Journal:  Cardiovasc Ultrasound       Date:  2013-11-06       Impact factor: 2.062

6.  Automated 3D geometry segmentation of the healthy and diseased carotid artery in free-hand, probe tracked ultrasound images.

Authors:  Joerik de Ruijter; Marc van Sambeek; Frans van de Vosse; Richard Lopata
Journal:  Med Phys       Date:  2020-01-03       Impact factor: 4.071

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.