Literature DB >> 21776779

Three-dimensional morphological analysis of intracranial aneurysms: a fully automated method for aneurysm sac isolation and quantification.

Ignacio Larrabide1, Maria Cruz Villa-Uriol, Rubén Cárdenes, Jose Maria Pozo, Juan Macho, Luis San Roman, Jordi Blasco, Elio Vivas, Alberto Marzo, D Rod Hose, Alejandro F Frangi.   

Abstract

PURPOSE: Morphological descriptors are practical and essential biomarkers for diagnosis and treatment selection for intracranial aneurysm management according to the current guidelines in use. Nevertheless, relatively little work has been dedicated to improve the three-dimensional quantification of aneurysmal morphology, to automate the analysis, and hence to reduce the inherent intra and interobserver variability of manual analysis. In this paper we propose a methodology for the automated isolation and morphological quantification of saccular intracranial aneurysms based on a 3D representation of the vascular anatomy.
METHOD: This methodology is based on the analysis of the vasculature skeleton's topology and the subsequent application of concepts from deformable cylinders. These are expanded inside the parent vessel to identify different regions and discriminate the aneurysm sac from the parent vessel wall. The method renders as output the surface representation of the isolated aneurysm sac, which can then be quantified automatically. The proposed method provides the means for identifying the aneurysm neck in a deterministic way. The results obtained by the method were assessed in two ways: they were compared to manual measurements obtained by three independent clinicians as normally done during diagnosis and to automated measurements from manually isolated aneurysms by three independent operators, nonclinicians, experts in vascular image analysis. All the measurements were obtained using in-house tools. The results were qualitatively and quantitatively compared for a set of the saccular intracranial aneurysms (n = 26).
RESULTS: Measurements performed on a synthetic phantom showed that the automated measurements obtained from manually isolated aneurysms where the most accurate. The differences between the measurements obtained by the clinicians and the manually isolated sacs were statistically significant (neck width: p <0.001, sac height: p = 0.002). When comparing clinicians' measurements to automatically isolated sacs, only the differences for the neck width were significant (neck width: p <0.001, sac height: p = 0.95). However, the correlation and agreement between the measurements obtained from manually and automatically isolated aneurysms for the neck width: p = 0.43 and sac height: p = 0.95 where found.
CONCLUSIONS: The proposed method allows the automated isolation of intracranial aneurysms, eliminating the interobserver variability. In average, the computational cost of the automated method (2 min 36 s) was similar to the time required by a manual operator (measurement by clinicians: 2 min 51 s, manual isolation: 2 min 21 s) but eliminating human interaction. The automated measurements are irrespective of the viewing angle, eliminating any bias or difference between the observer criteria. Finally, the qualitative assessment of the results showed acceptable agreement between manually and automatically isolated aneurysms.

Entities:  

Mesh:

Year:  2011        PMID: 21776779     DOI: 10.1118/1.3575417

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

Review 1.  Artificial Intelligence in the Management of Intracranial Aneurysms: Current Status and Future Perspectives.

Authors:  Z Shi; B Hu; U J Schoepf; R H Savage; D M Dargis; C W Pan; X L Li; Q Q Ni; G M Lu; L J Zhang
Journal:  AJNR Am J Neuroradiol       Date:  2020-03-12       Impact factor: 3.825

2.  Computer-Assisted Three-Dimensional Morphology Evaluation of Intracranial Aneurysms.

Authors:  Hamidreza Rajabzadeh-Oghaz; Nicole Varble; Hussain Shallwani; Vincent M Tutino; Ashkan Mowla; Hakeem J Shakir; Kunal Vakharia; Gursant S Atwal; Adnan H Siddiqui; Jason M Davies; Hui Meng
Journal:  World Neurosurg       Date:  2018-08-01       Impact factor: 2.104

3.  Performance assessment of isolation methods for geometrical cerebral aneurysm analysis.

Authors:  Rubén Cárdenes; Ignacio Larrabide; Luis San Román; Alejandro F Frangi
Journal:  Med Biol Eng Comput       Date:  2012-12-06       Impact factor: 2.602

4.  Comparison of 3D computer-aided with manual cerebral aneurysm measurements in different imaging modalities.

Authors:  M Groth; N D Forkert; J H Buhk; M Schoenfeld; E Goebell; J Fiehler
Journal:  Neuroradiology       Date:  2012-09-25       Impact factor: 2.804

Review 5.  Factors affecting formation and rupture of intracranial saccular aneurysms.

Authors:  S Bacigaluppi; M Piccinelli; L Antiga; A Veneziani; T Passerini; P Rampini; M Zavanone; P Severi; G Tredici; G Zona; T Krings; E Boccardi; S Penco; M Fontanella
Journal:  Neurosurg Rev       Date:  2013-12-04       Impact factor: 3.042

6.  Reliability and accuracy assessment of morphometric measurements obtained with software for three-dimensional reconstruction of brain aneurysms relative to cerebral angiography measures.

Authors:  Pablo M Munarriz; Eduardo Bárcena; Jose F Alén; Ana M Castaño-Leon; Igor Paredes; Luis Miguel Moreno-Gómez; Daniel García-Pérez; Luis Jiménez-Roldán; Pedro A Gómez; Alfonso Lagares
Journal:  Interv Neuroradiol       Date:  2020-09-30       Impact factor: 1.610

  6 in total