Literature DB >> 21774871

D(max) for stereoscopic depth perception with simulated monovision correction.

Jin Qian1, Samuel A Adeseye, Scott B Stevenson, Saumil S Patel, Harold E Bedell.   

Abstract

PURPOSE: Persons who wear monovision correction typically receive a clear image in one eye and a blurred image in the other eye. Although monovision is known to elevate the minimum stereoscopic threshold (Dmin), it is uncertain how it influences the largest binocular disparity for which the direction of depth can reliably be perceived (Dmax). In this study, we compared Dmax for stereo when one eye's image is blurred to Dmax when both eyes' images are either clear or blurred.
METHODS: The stimulus was a pair of vertically oriented, random-line patterns. To simulate monovision correction with +1.5 or +2.5 D defocus, the images of the line patterns presented to one eye were spatially low-pass filtered while the patterns presented to the other eye remained unfiltered.
RESULTS: Compared to binocular viewing without blur, Dmin is elevated substantially more in the presence of monocular than binocular simulated blur. Dmax is reduced in the presence of simulated monocular blur by between 13 and 44%, compared to when the images in both eyes are clear. In contrast, when the targets presented to both eyes are blurred equally, Dmax either is unchanged or increases slightly, compared to the values measured with no blur.
CONCLUSION: In conjunction with the elevation of Dmin, the reduction of Dmax with monocular blur indicates that the range of useful stereoscopic depth perception is likely to be compressed in patients who wear monovision corrections.

Entities:  

Mesh:

Year:  2012        PMID: 21774871     DOI: 10.1163/187847511X579043

Source DB:  PubMed          Journal:  Seeing Perceiving


  4 in total

1.  Perceived suprathreshold depth under conditions that elevate the stereothreshold.

Authors:  Harold E Bedell; Liat Gantz; Danielle N Jackson
Journal:  Optom Vis Sci       Date:  2012-12       Impact factor: 1.973

2.  LogMAR and Stereoacuity in Keratoconus Corrected with Spectacles and Rigid Gas-permeable Contact Lenses.

Authors:  Vinay Kumar Nilagiri; Sangeetha Metlapally; Parthasarathi Kalaiselvan; Clifton M Schor; Shrikant R Bharadwaj
Journal:  Optom Vis Sci       Date:  2018-04       Impact factor: 1.973

3.  Monocular blur alters the tuning characteristics of stereopsis for spatial frequency and size.

Authors:  Roger W Li; Kayee So; Thomas H Wu; Ashley P Craven; Truyet T Tran; Kevin M Gustafson; Dennis M Levi
Journal:  R Soc Open Sci       Date:  2016-09-21       Impact factor: 2.963

4.  A computational analysis of retinal image quality in eyes with keratoconus.

Authors:  Vinay Kumar Nilagiri; Sangeetha Metlapally; Clifton M Schor; Shrikant R Bharadwaj
Journal:  Sci Rep       Date:  2020-01-28       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.