Literature DB >> 21768704

Dose variation during hypofractionated image-guided radiotherapy for prostate cancer: planned versus delivered.

Vedang Murthy1, Pragya Shukla, Pranjal Adurkar, Zubin Master, Umesh Mahantshetty, Shyam K Shrivastava.   

Abstract

AIMS: To determine variation in the actual doses delivered to the organs at risk and the target in patients treated for localized carcinoma of the prostate using image-guided radiotherapy.
MATERIALS AND METHODS: Ten patients treated with helical TomoTherapy underwent daily target localization with megavoltage CT, on which the prostate, rectum and bladder were recontoured. The planned adaptive module was used for dose recalculation. The study endpoints were to analyse the variations in certain dose-volume parameters of the rectum and bladder (BD 2cc , RD 2cc , BV 100% , BV 70% , RV 100% , RV 70% ), the maximum anteroposterior (AP) and lateral rectal diameters, the volume of the CTV receiving 100% of the prescription dose (CTV V 100% ) and the dose to 100% of the CTV (CTV D 100% ).
RESULTS: The difference between the planned and delivered target doses (CTV V100% and CTV D100%) was small and clinically insignificant indicating adequate target coverage during treatment. There was a large variation in the AP and lateral rectal diameters, with no particular trend or correlation to dose parameters being noted during the course of treatment. The mean AP diameter during treatment was significantly less than the planned diameter (P < 0.05). The percentage of fractions where the delivered BV100%, BV70%, RV100%, and RV70% was more than the planned values were 42.8%, 17.1%, 45.4%, and 44.4%, respectively. The delivered BD2cc and RD2cc were similar to their planned values.
CONCLUSIONS: This study demonstrates the usefulness of daily soft tissue image guidance in negating the effects of physiological variation of the rectum and bladder on the dose delivered to the prostate.

Entities:  

Mesh:

Year:  2011        PMID: 21768704     DOI: 10.4103/0973-1482.82920

Source DB:  PubMed          Journal:  J Cancer Res Ther        ISSN: 1998-4138            Impact factor:   1.805


  7 in total

1.  Dosimetric and volumetric effects in clinical target volume and organs at risk during postprostatectomy radiotherapy.

Authors:  Ahmed Gawish; Ahmed Ali Chughtai; Michael J Eble
Journal:  Strahlenther Onkol       Date:  2018-10-17       Impact factor: 3.621

2.  The Usefulness of Adaptative Radiotherapy in Prostate Cancer: How, When, and Who?

Authors:  Rodrigo Muelas-Soria; Rafael García-Mollá; Virginia Morillo-Macías; Jorge Bonaque-Alandí; Patricia Sorribes-Carreras; Francisco García-Piñón; Carlos Ferrer-Albiach
Journal:  Biomedicines       Date:  2022-06-13

Review 3.  Exploiting biological and physical determinants of radiotherapy toxicity to individualize treatment.

Authors:  J E Scaife; G C Barnett; D J Noble; R Jena; S J Thomas; C M L West; N G Burnet
Journal:  Br J Radiol       Date:  2015-05-26       Impact factor: 3.039

4.  Random variation in rectal position during radiotherapy for prostate cancer is two to three times greater than that predicted from prostate motion.

Authors:  J Scaife; K Harrison; M Romanchikova; A Parker; M Sutcliffe; S Bond; S Thomas; S Freeman; R Jena; A Bates; N Burnet
Journal:  Br J Radiol       Date:  2014-08-20       Impact factor: 3.039

5.  Recalculation of dose for each fraction of treatment on TomoTherapy.

Authors:  Simon J Thomas; Marina Romanchikova; Karl Harrison; Michael A Parker; Amy M Bates; Jessica E Scaife; Michael P F Sutcliffe; Neil G Burnet
Journal:  Br J Radiol       Date:  2016-01-05       Impact factor: 3.039

6.  Accumulated dose to the rectum, measured using dose-volume histograms and dose-surface maps, is different from planned dose in all patients treated with radiotherapy for prostate cancer.

Authors:  Jessica E Scaife; Simon J Thomas; Karl Harrison; Marina Romanchikova; Michael P F Sutcliffe; Julia R Forman; Amy M Bates; Raj Jena; M Andrew Parker; Neil G Burnet
Journal:  Br J Radiol       Date:  2015-07-24       Impact factor: 3.039

7.  A framework for deformable image registration validation in radiotherapy clinical applications.

Authors:  Raj Varadhan; Grigorios Karangelis; Karthik Krishnan; Susanta Hui
Journal:  J Appl Clin Med Phys       Date:  2013-01-02       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.