Abstract

A new approach is proposed for synthesizing the standard 12-lead ECG from three differential leads formed by pairs of proximal electrodes on the body surface. The method is supported by a statistical analysis that gives the best personalized positions of electrodes. The measurements from multichannel ECGs were used to calculate the differential leads. Our algorithm searches for optimal differential leads and the corresponding personalized transformation matrix that is used to synthesize the standard 12-lead ECG. The algorithm has been evaluated on 99 multichannel ECGs measured on 30 healthy subjects and 35 patients scheduled for elective cardiac surgery. It is shown that the algorithm significantly outperforms the synthesis based on the EASI lead system with medians of correlation coefficients greater than 0.954 for all 12 standard leads. To determine the optimal number of differential leads, the syntheses for two, three, and four differential leads were calculated. The analysis shows that 3 is the optimal number of differential leads for practical applications. Because of the proximity of the differential electrodes, the proposed approach offers an opportunity for the synthesis of a standard 12-lead ECG with wireless electrodes.

Entities:  

Mesh:

Year:  2011        PMID: 21768013     DOI: 10.1109/TITB.2011.2159236

Source DB:  PubMed          Journal:  IEEE Trans Inf Technol Biomed        ISSN: 1089-7771


  7 in total

1.  Pareto optimization for electrodes placement: compromises between electrophysiological and practical aspects.

Authors:  Indra Hardian Mulyadi; Patrique Fiedler; Roland Eichardt; Jens Haueisen; Eko Supriyanto
Journal:  Med Biol Eng Comput       Date:  2021-01-26       Impact factor: 2.602

Review 2.  Continuous remote monitoring of COPD patients-justification and explanation of the requirements and a survey of the available technologies.

Authors:  Ivan Tomasic; Nikica Tomasic; Roman Trobec; Miroslav Krpan; Tomislav Kelava
Journal:  Med Biol Eng Comput       Date:  2018-03-05       Impact factor: 2.602

3.  Reconstruction of 12-Lead Electrocardiogram from a Three-Lead Patch-Type Device Using a LSTM Network.

Authors:  Jangjay Sohn; Seungman Yang; Joonnyong Lee; Yunseo Ku; Hee Chan Kim
Journal:  Sensors (Basel)       Date:  2020-06-09       Impact factor: 3.576

4.  Power Autonomy Estimation of Low-Power Sensor for Long-Term ECG Monitoring.

Authors:  Klemen Bregar; Tomaž Krištofelc; Matjaž Depolli; Viktor Avbelj; Aleksandra Rashkovska
Journal:  Sensors (Basel)       Date:  2022-07-06       Impact factor: 3.847

5.  Two proximal skin electrodes--a respiration rate body sensor.

Authors:  Roman Trobec; Aleksandra Rashkovska; Viktor Avbelj
Journal:  Sensors (Basel)       Date:  2012-10-15       Impact factor: 3.576

6.  A lightweight piecewise linear synthesis method for standard 12-lead ECG signals based on adaptive region segmentation.

Authors:  Huaiyu Zhu; Yun Pan; Kwang-Ting Cheng; Ruohong Huan
Journal:  PLoS One       Date:  2018-10-19       Impact factor: 3.240

7.  Medical-Grade ECG Sensor for Long-Term Monitoring.

Authors:  Aleksandra Rashkovska; Matjaž Depolli; Ivan Tomašić; Viktor Avbelj; Roman Trobec
Journal:  Sensors (Basel)       Date:  2020-03-18       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.