Abstract

The aim of the present study was to measure the accuracy of the cone-beam computerized tomography (CBCT)- aided StentCad Beyond surgical guidance system and to compare bone-supported and tooth/bone-supported guidance by using this system in dental implant placement ex vivo. Five cadaver mandibles were scanned using an Iluma CBCT scanner. After scanning, DICOM slices were transferred to the StentCad Beyond implant simulation software, which was used for preoperative implant planning. Using the StentCad Beyond guidance system, 9 implant drills were inserted using a bone-supported guidance system and 11 using a tooth/bone-supported guidance system. Mandibles were scanned again and these data were transferred to the StentCad Beyond software. Pre- and postoperative information was superimposed using the Rhinoceros version 4 software program, and deviations between planned and actual drill positions were calculated for each implant. In addition, differences between bone-supported and tooth/bone-supported guidance systems were analyzed by t-test, with a significance level of P < .05. Data analysis found a mean coronal deviation of 1.2 ± 0.3 mm and 0.6 ± 0.6 mm, mean apical deviation of 1.3 ± 0.6 mm and 0.7 ± 0.6 mm, mean apical and coronal depth deviation of 1.4 ± 0.3 mm and 1.3 ± 0.3 mm, and mean angular deviation of 4.2° ± 2.0° and 3.0° ± 1.5° for tooth/bone supported and bone-supported guides, respectively. No statistical differences were found in depth or angular deviations between groups (P > .05); however, statistically significant differences between groups were found in mean horizontal coronal deviation (P = .016) and mean horizontal apical deviation (P = .047). The StentCad Beyond system was found to be a reliable guide for placing implants ex vivo.

Entities:  

Mesh:

Year:  2011        PMID: 21767205     DOI: 10.1563/AAID-JOI-D-11-00062

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  2 in total

1.  Implant Bed Preparation with an Erbium, Chromium Doped Yttrium Scandium Gallium Garnet (Er,Cr: YSGG) Laser Using Stereolithographic Surgical Guide.

Authors:  Gülin Seymen; Zeynep Turgut; Gizem Berk; Ayşen Bodur
Journal:  J Lasers Med Sci       Date:  2013

2.  Accuracy of computer-assisted surgery in immediate implant placement: An experimental study.

Authors:  Nicole Báez-Marrero; José Luis Rafel; Yalil Augusto Rodríguez-Cárdenas; Aron Aliaga-Del Castillo; Heraldo Luis Dias-Da Silveira; Luis Ernesto Arriola-Guillén
Journal:  J Indian Soc Periodontol       Date:  2021-09-27
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.