[Reference values in abdominal ultrasound - biliopancreatic system and spleen].

M Sienz1, A Ignee, C F Dietrich.   

Abstract

OBJECTIVE: Reference values for B-mode abdominal ultrasound are controversially discussed due to the limited data in the literature. A systematic survey of the data published so far is presented for the biliopancreatic system and the spleen.
METHODS: A literature review of reference values in the abdomen from 1970 to 2010 in healthy subjects 18 years of age and older was carried out. According to the determination of reference intervals for laboratory values, reference values are generally determined using 95 %-reference intervals and their associated 90 %-confidence intervals. The gallbladder, gallbladder wall, bile ducts, pancreas and the spleen were evaluated.
RESULTS: 70 studies were analysed. The comparability of the data is limited, because different collectives were studied and diverse measuring techniques were used. In particular, gallbladder volume measurements reported in the literature differ substantially. Data for the size of the gallbladder are insufficient. Deducible reference values for the common hepatic duct or, respectively, the common bile duct lie between 5 and 9 mm in dependency on the measuring position and the collective analysed. The published measurement values for the size of the pancreas also vary considerably. In most of the publications the upper limit of normal for the length of the spleen amounts to around 12 cm, in young, athletic men up to 15 cm. DISCUSSION: Normal values are helpful in delimiting numerous pathological changes in the respective organs. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2011        PMID: 21766264     DOI: 10.1055/s-0031-1273362

Source DB:  PubMed          Journal:  Z Gastroenterol        ISSN: 0044-2771            Impact factor:   2.000


  2 in total

Review 1.  Fortuitously discovered liver lesions.

Authors:  Christoph F Dietrich; Malay Sharma; Robert N Gibson; Dagmar Schreiber-Dietrich; Christian Jenssen
Journal:  World J Gastroenterol       Date:  2013-06-07       Impact factor: 5.742

Review 2.  What should be known prior to performing EUS exams? (Part II).

Authors:  Christoph F Dietrich; Paolo Giorgio Arcidiacono; Barbara Braden; Sean Burmeister; Silvia Carrara; Xinwu Cui; Milena Di Leo; Yi Dong; Pietro Fusaroli; Uwe Gottschalk; Andrew J Healey; Michael Hocke; Stephan Hollerbach; Julio Iglesias Garcia; André Ignee; Christian Jürgensen; Michel Kahaleh; Masayuki Kitano; Rastislav Kunda; Alberto Larghi; Kathleen Möller; Bertrand Napoleon; Kofi W Oppong; Maria Chiara Petrone; Adrian Saftoiu; Rajesh Puri; Anand V Sahai; Erwin Santo; Malay Sharma; Assaad Soweid; Siyu Sun; Anthony Yuen Bun Teoh; Peter Vilmann; Hans Seifert; Christian Jenssen
Journal:  Endosc Ultrasound       Date:  2019 Nov-Dec       Impact factor: 5.628

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.