Safety and efficacy of frequency domain optical coherence tomography in pigs.

Xiankai Li1, Joseph W Villard, Yongjian Ouyang, Joel E Michalek, Refat Jabara, Dan Sims, Nate Kemp, Tim Glynn, Christopher Banas, Steven R Bailey, Marc D Feldman.   

Abstract

AIMS: To determine the safety and efficacy of frequency domain OCT, which can scan at much higher rates and make it possible to avoid an occlusion balloon and image during an angiographic injection through guide catheter. The catheters have diameters ranging from 2.7 to 3.5 Fr. The presence of the imaging catheter increases fluid resistance to the injection of viscous solutions necessary for clearing the blood. METHODS AND
RESULTS: The Volcano 3.5 Fr frequency domain OCT catheter system was investigated for safety in (a) n=10 porcine studies using acute and 30-day histology, and (b) for efficacy in n=9 in vivo porcine coronary arteries. We found: (a) frequency domain imaging is safe in the porcine model using histology as an endpoint; (b) the addition of a viscous contrast (iodixonal) to saline is superior for lumen clearance compared to saline alone; (c) hand injection, 4 ml/sec, and 6 ml/sec power injection all provided similar vessel wall clearance; (d) the anticipated loss of vessel wall visualisation with left main injection (due to half the injectate in the non-imaged vessel) was not evident in proximal and middle coronary artery OCT catheter positions.
CONCLUSIONS: Frequency domain OCT is safe and efficacious in the porcine model.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21764669     DOI: 10.4244/EIJV7I4A80

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  2 in total

1.  An assessment of the quality of optical coherence tomography image acquisition.

Authors:  Elder Iarossi Zago; Abdul Jawwad Samdani; Gabriel Tensol Rodrigues Pereira; Armando Vergara-Martel; Mohamad Amer Alaiti; Luis Augusto Dallan; Patricia Ely Pizzato; Vladislav Zimin; Anas Fares; Hiram G Bezerra
Journal:  Int J Cardiovasc Imaging       Date:  2020-02-18       Impact factor: 2.357

2.  Frequency-domain optical coherence tomography assessment of human carotid atherosclerosis using saline flush for blood clearance without balloon occlusion.

Authors:  C A Given; G F Attizzani; M R Jones; C N Ramsey; W H Brooks; M A Costa; H G Bezerra
Journal:  AJNR Am J Neuroradiol       Date:  2013-02-07       Impact factor: 3.825

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.