Literature DB >> 21763663

Potential of long chain ionic liquids for on-line sample concentration techniques: application to micelle to solvent stacking.

Joselito P Quirino1, Philippe Anres, Juliette Sirieix-Plénet, Nathalie Delaunay, Pierre Gareil.   

Abstract

The performance of micelle to solvent stacking (MSS) in capillary zone electrophoresis (CZE) was improved for anionic analytes using the long chain ionic liquid type cationic surfactant 1-dodecyl-3-methylimidazolium tetrafluoroborate (C₁₂-MIM-BF₄). The peak heights and corrected peak areas of the test profens and herbicides were enhanced up to 59 and 110-fold, respectively when compared to typical injection. These were up to 10 times better compared to the surfactant cetyltrimethyl ammonium bromide as MSS carrier. This performance was attributed to the properties of C₁₂-MIM-BF₄. MSS requires micelles in the sample for transport of bound analytes to a stacking boundary that contains an organic solvent for effective electrophoretic mobility reversal. The ionic liquid micelles provided better analyte transport properties that resulted from its hydrophobic and pi-pi interaction capabilities. The good solubility of the ionic liquid in high percentages of organic solvent also facilitated a more effective reversal of mobility. The LODs obtained for the test analytes were from 0.06 to 0.12 μg/mL. The linearity R² values in terms of peak height and corrected area were ≥ 0.99. The interday repeatabilities (%RSD, n=10,) were 0.5-2.2% for retention time, 1.9-4.7% for corrected areas and 4.1-6.4% for peak heights. Crown
Copyright © 2011. Published by Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21763663     DOI: 10.1016/j.chroma.2011.06.071

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

1.  Sweeping-micelle to solvent stacking for the on-line preconcentration and determination of organic acids in Angelica sinensis by capillary electrophoresis.

Authors:  Xiumin Yang; Lin Hao; Shuaihua Zhang; Chun Wang; Zhi Wang
Journal:  RSC Adv       Date:  2018-02-20       Impact factor: 3.361

Review 2.  Recent Advances in the Determination of Pesticides in Environmental Samples by Capillary Electrophoresis.

Authors:  Po-Ling Chang; Ming-Mu Hsieh; Tai-Chia Chiu
Journal:  Int J Environ Res Public Health       Date:  2016-04-08       Impact factor: 3.390

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.