Literature DB >> 21761697

Probabilistic elastography: estimating lung elasticity.

Petter Risholm1, James Ross, George R Washko, William M Wells.   

Abstract

We formulate registration-based elastography in a probabilistic framework and apply it to study lung elasticity in the presence of emphysematous and fibrotic tissue. The elasticity calculations are based on a Finite Element discretization of a linear elastic biomechanical model. We marginalize over the boundary conditions (deformation) of the biomechanical model to determine the posterior distribution over elasticity parameters. Image similarity is included in the likelihood, an elastic prior is included to constrain the boundary conditions, while a Markov model is used to spatially smooth the inhomogeneous elasticity. We use a Markov Chain Monte Carlo (MCMC) technique to characterize the posterior distribution over elasticity from which we extract the most probable elasticity as well as the uncertainty of this estimate. Even though registration-based lung elastography with inhomogeneous elasticity is challenging due the problem's highly underdetermined nature and the sparse image information available in lung CT, we show promising preliminary results on estimating lung elasticity contrast in the presence of emphysematous and fibrotic tissue.

Entities:  

Mesh:

Year:  2011        PMID: 21761697      PMCID: PMC3249413          DOI: 10.1007/978-3-642-22092-0_57

Source DB:  PubMed          Journal:  Inf Process Med Imaging        ISSN: 1011-2499


  9 in total

1.  A new approach to elastography using mutual information and finite elements.

Authors:  Michael I Miga
Journal:  Phys Med Biol       Date:  2003-02-21       Impact factor: 3.609

2.  Summarizing and visualizing uncertainty in non-rigid registration.

Authors:  Petter Risholm; Steve Pieper; Eigil Samset; William M Wells
Journal:  Med Image Comput Comput Assist Interv       Date:  2010

3.  MR elastography of the lung with hyperpolarized 3He.

Authors:  Kiaran P McGee; Rolf D Hubmayr; R L Ehman
Journal:  Magn Reson Med       Date:  2008-01       Impact factor: 4.668

4.  Evaluation of 3D modality-independent elastography for breast imaging: a simulation study.

Authors:  J J Ou; R E Ong; T E Yankeelov; M I Miga
Journal:  Phys Med Biol       Date:  2007-12-19       Impact factor: 3.609

5.  Weight preserving image registration for monitoring disease progression in lung CT.

Authors:  Vladlena Gorbunova; Pechin Lol; Haseem Ashraf; Asger Dirksen; Mads Nielsen; Marleen de Bruijne
Journal:  Med Image Comput Comput Assist Interv       Date:  2008

6.  Mass preserving nonrigid registration of CT lung images using cubic B-spline.

Authors:  Youbing Yin; Eric A Hoffman; Ching-Long Lin
Journal:  Med Phys       Date:  2009-09       Impact factor: 4.071

7.  Lung extraction, lobe segmentation and hierarchical region assessment for quantitative analysis on high resolution computed tomography images.

Authors:  James C Ross; Raúl San José Estépar; Alejandro Díaz; Carl-Fredrik Westin; Ron Kikinis; Edwin K Silverman; George R Washko
Journal:  Med Image Comput Comput Assist Interv       Date:  2009

8.  Sliding characteristic and material compressibility of human lung: parametric study and verification.

Authors:  A Al-Mayah; J Moseley; M Velec; K K Brock
Journal:  Med Phys       Date:  2009-10       Impact factor: 4.071

9.  Thin-section CT of the secondary pulmonary lobule: anatomy and the image--the 2004 Fleischner lecture.

Authors:  W Richard Webb
Journal:  Radiology       Date:  2006-03-16       Impact factor: 11.105

  9 in total
  2 in total

1.  Validation of a nonrigid registration error detection algorithm using clinical MRI brain data.

Authors:  Ryan D Datteri; Yuan Liu; Pierre-Francois D'Haese; Benoit M Dawant
Journal:  IEEE Trans Med Imaging       Date:  2014-07-30       Impact factor: 10.048

2.  A personalized biomechanical model for respiratory motion prediction.

Authors:  B Fuerst; T Mansi; Jianwen Zhang; P Khurd; J Declerck; T Boettger; Nassir Navab; J Bayouth; Dorin Comaniciu; A Kamen
Journal:  Med Image Comput Comput Assist Interv       Date:  2012
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.