Comparison of the performance characteristics of two tubular contactless conductivity detectors with different dimensions and application in conjunction with HPLC.

Jonas Josef Peter Mark1, Pavel Coufal, Frantisek Opekar, Frank-Michael Matysik.   

Abstract

Two tubular capacitively coupled contactless conductivity detection (C(4)D) cells with different geometric dimensions were evaluated with regard to their main analytical characteristics under non-separation and separation conditions in conjunction with liquid chromatography. A comparison of the performance of the tubular cells to a previously tested thin-layer detection cell was drawn. Additionally, using a theoretical model the experimental results were compared with sets of calculated values and partially enabled to model the complex behavior of C(4)D detection in combination with high-performance liquid chromatography (HPLC). While cell 1 is characterized by a geometric cell volume of 0.6 μL, a wall thickness of 675 μm, and an inner diameter of 125 μm, the respective values for cell 2 are 2.3 μL, 200 μm, and 250 μm. The main analytical parameters were evaluated using a potassium chloride (KCl) solution. The limits of detection were 0.4 μM KCl (5.7 × 10(-6) S m(-1)) for cell 1 and 0.2 μM KCl (3.2 × 10(-6) S m(-1)) for cell 2, which compares well to the previously found 0.2 μM for the thin-layer cell. A pair of linear ranges was found for both cells in a concentration interval ranging from 1 × 10(-6) to 1 × 10(-4) M (corresponding to 1.5 × 10(-5) to 1.5 × 10(-3) S m(-1)) KCl, respectively. Furthermore, the detector cells were applied to the HPLC separation of a model compound system consisting of benzoic acid, lactic acid, octanesulphonic acid, and sodium capronate. Separation of the compounds was achieved with a Biospher PSI 100 C18 column using 60% aqueous acetonitrile mobile phase. Calibration curves for the examined model system were well correlated (r² > 0.997), and it was found that under separation conditions the arrangement with the lower cell volume (cell 1) yields higher sensitivity and respectively lower limits of detection for all model compounds. Compared with the thin-layer cell, the tubular cells show better overall performance in regard to the determined analytical characteristics.

Entities:  

Year:  2011        PMID: 21761108     DOI: 10.1007/s00216-011-5233-7

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  3 in total

1.  Investigation of the Effects of Electrode Geometry on the Performance of C4D Sensor with Radial Configuration.

Authors:  Qiang Huang; Junchao Huang; Yandan Jiang; Haifeng Ji; Baoliang Wang; Zhiyao Huang
Journal:  Sensors (Basel)       Date:  2021-06-29       Impact factor: 3.576

Review 2.  Contactless impedance sensors and their application to flow measurements.

Authors:  František Opekar; Petr Tůma; Karel Stulík
Journal:  Sensors (Basel)       Date:  2013-02-27       Impact factor: 3.576

3.  Ultracompact three-dimensional tubular conductivity microsensors for ionic and biosensing applications.

Authors:  Cynthia S Martinez-Cisneros; Samuel Sanchez; Wang Xi; Oliver G Schmidt
Journal:  Nano Lett       Date:  2014-03-27       Impact factor: 11.189

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.