Literature DB >> 21757605

Improved flagging rates on the Sysmex XE-5000 compared with the XE-2100 reduce the number of manual film reviews and increase laboratory productivity.

Carol J Briggs1, Joachim Linssen, Ian Longair, Samuel J Machin.   

Abstract

Hematology analyzers generate suspect flags in the presence of abnormal cells. False-positive rates for flags are high on all analyzers. Sysmex, Kobe, Japan, has developed new software for its XE-5000 with improved algorithms for flagging blast cells, abnormal lymphocytes or lymphoblasts, and atypical lymphocytes. This study evaluated the efficiency of these flags in 1,002 samples. The XE-5000 was compared with the XE-2100 (Sysmex) and microscopic examination of cell morphologic features. On the XE-2100, the blast flag demonstrated 90 false-positives, 13 true-positives, and 3 false-negatives. The values on the XE-5000 were 27 false-positives, 14 true-positives, and 2 false-negatives. The abnormal lymphocyte/lymphoblast flag was assessed with the atypical lymphocyte flag. The XE-2100 showed 114 false-positives, 23 true-positives, and 20 false-negatives, and on the XE-5000, there were 45 false-positives, 22 true-positives, and 21 false-negatives. This more specific flagging reduces the number of films that require manual review.

Entities:  

Mesh:

Year:  2011        PMID: 21757605     DOI: 10.1309/AJCPDLR4KGKAFW4W

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  6 in total

1.  Performance evaluation of the white cell precursor channel on the Sysmex XN hematology analyzer in HIV specimens.

Authors:  Elise Schapkaitz; Phoyisile Khoza
Journal:  J Clin Lab Anal       Date:  2017-09-26       Impact factor: 2.352

2.  Detection of Apoptotic Lymphocytes Through Sysmex XN-1000 As a Diagnostic Marker for Mononucleosis Syndrome.

Authors:  Silvia Sale; Addolorata Emanuela Carone; Maurizio Fumi; Ylenia Pancione; Vincenzo Rocco
Journal:  J Clin Lab Anal       Date:  2016-04-19       Impact factor: 2.352

3.  Why and how validate criteria by manual smear review to improve laboratory productivity?

Authors:  Helena Zerlotti Wolf Grotto
Journal:  Rev Bras Hematol Hemoter       Date:  2014-11-20

4.  Utility of Peripheral Film Findings and its Correlation with Automated Analyzer - An Audit from Tertiary Care Hospital.

Authors:  Sidra Asad; Imran Ahmed; Natasha Ali
Journal:  J Lab Physicians       Date:  2017 Jan-Mar

5.  Validation of a DNA methylation reference panel for the estimation of nucleated cells types in cord blood.

Authors:  Andres Cardenas; Catherine Allard; Myriam Doyon; E Andres Houseman; Kelly M Bakulski; Patrice Perron; Luigi Bouchard; Marie-France Hivert
Journal:  Epigenetics       Date:  2016-09-26       Impact factor: 4.528

6.  A novel haemocytometric COVID-19 prognostic score developed and validated in an observational multicentre European hospital-based study.

Authors:  Joachim Linssen; Anthony Ermens; Marvin Berrevoets; Michela Seghezzi; Giulia Previtali; Simone van der Sar-van der Brugge; Henk Russcher; Annelies Verbon; Judith Gillis; Jürgen Riedl; Eva de Jongh; Jarob Saker; Marion Münster; Imke Ca Munnix; Anthonius Dofferhof; Volkher Scharnhorst; Heidi Ammerlaan; Kathleen Deiteren; Stephan Jl Bakker; Lucas Joost Van Pelt; Yvette Kluiters-de Hingh; Mathie Pg Leers; Andre J van der Ven
Journal:  Elife       Date:  2020-11-26       Impact factor: 8.140

  6 in total