Literature DB >> 21755548

Spectral analysis software improves confidence in plant and soil water stable isotope analyses performed by isotope ratio infrared spectroscopy (IRIS).

A G West1, G R Goldsmith, I Matimati, T E Dawson.   

Abstract

Previous studies have demonstrated the potential for large errors to occur when analyzing waters containing organic contaminants using isotope ratio infrared spectroscopy (IRIS). In an attempt to address this problem, IRIS manufacturers now provide post-processing spectral analysis software capable of identifying samples with the types of spectral interference that compromises their stable isotope analysis. Here we report two independent tests of this post-processing spectral analysis software on two IRIS systems, OA-ICOS (Los Gatos Research Inc.) and WS-CRDS (Picarro Inc.). Following a similar methodology to a previous study, we cryogenically extracted plant leaf water and soil water and measured the δ(2)H and δ(18)O values of identical samples by isotope ratio mass spectrometry (IRMS) and IRIS. As an additional test, we analyzed plant stem waters and tap waters by IRMS and IRIS in an independent laboratory. For all tests we assumed that the IRMS value represented the "true" value against which we could compare the stable isotope results from the IRIS methods. Samples showing significant deviations from the IRMS value (>2σ) were considered to be contaminated and representative of spectral interference in the IRIS measurement. Over the two studies, 83% of plant species were considered contaminated on OA-ICOS and 58% on WS-CRDS. Post-analysis, spectra were analyzed using the manufacturer's spectral analysis software, in order to see if the software correctly identified contaminated samples. In our tests the software performed well, identifying all the samples with major errors. However, some false negatives indicate that user evaluation and testing of the software are necessary. Repeat sampling of plants showed considerable variation in the discrepancies between IRIS and IRMS. As such, we recommend that spectral analysis of IRIS data must be incorporated into standard post-processing routines. Furthermore, we suggest that the results from spectral analysis be included when reporting stable isotope data from IRIS.
Copyright © 2011 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21755548     DOI: 10.1002/rcm.5126

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  3 in total

1.  Sustained wood burial in the Bengal Fan over the last 19 My.

Authors:  Hyejung Lee; Valier Galy; Xiaojuan Feng; Camilo Ponton; Albert Galy; Christian France-Lanord; Sarah J Feakins
Journal:  Proc Natl Acad Sci U S A       Date:  2019-10-21       Impact factor: 11.205

2.  Borehole Equilibration: Testing a New Method to Monitor the Isotopic Composition of Tree Xylem Water in situ.

Authors:  John D Marshall; Matthias Cuntz; Matthias Beyer; Maren Dubbert; Kathrin Kuehnhammer
Journal:  Front Plant Sci       Date:  2020-04-15       Impact factor: 5.753

3.  Simultaneous analysis of (17) O/(16) O, (18) O/(16) O and (2) H/(1) H of gypsum hydration water by cavity ring-down laser spectroscopy.

Authors:  Fernando Gázquez; Ian Mather; James Rolfe; Nicholas P Evans; Daniel Herwartz; Michael Staubwasser; David A Hodell
Journal:  Rapid Commun Mass Spectrom       Date:  2015-11-15       Impact factor: 2.419

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.