Maximum-likelihood scintillation detection for EM-CCD based gamma cameras.

Marc A N Korevaar1, Marlies C Goorden, Jan W T Heemskerk, Freek J Beekman.   

Abstract

Gamma cameras based on charge-coupled devices (CCDs) coupled to continuous scintillation crystals can combine a good detection efficiency with high spatial resolutions with the aid of advanced scintillation detection algorithms. A previously developed analytical multi-scale algorithm (MSA) models the depth-dependent light distribution but does not take statistics into account. Here we present and validate a novel statistical maximum-likelihood algorithm (MLA) that combines a realistic light distribution model with an experimentally validated statistical model. The MLA was tested for an electron multiplying CCD optically coupled to CsI(Tl) scintillators of different thicknesses. For (99m)Tc imaging, the spatial resolution (for perpendicular and oblique incidence), energy resolution and signal-to-background counts ratio (SBR) obtained with the MLA were compared with those of the MSA. Compared to the MSA, the MLA improves the energy resolution by more than a factor of 1.6 and the SBR is enhanced by more than a factor of 1.3. For oblique incidence (approximately 45°), the depth-of-interaction corrected spatial resolution is improved by a factor of at least 1.1, while for perpendicular incidence the MLA resolution does not consistently differ significantly from the MSA result for all tested scintillator thicknesses. For the thickest scintillator (3 mm, interaction probability 66% at 141 keV) a spatial resolution (perpendicular incidence) of 147 µm full width at half maximum (FWHM) was obtained with an energy resolution of 35.2% FWHM. These results of the MLA were achieved without prior calibration of scintillations as is needed for many statistical scintillation detection algorithms. We conclude that the MLA significantly improves the gamma camera performance compared to the MSA.

Entities:  

Mesh:

Year:  2011        PMID: 21753231     DOI: 10.1088/0031-9155/56/15/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  2 in total

1.  A gain series method for accurate EMCCD calibration.

Authors:  Duncan P Ryan; Megan K Dunlap; Martin P Gelfand; James H Werner; Alan K Van Orden; Peter M Goodwin
Journal:  Sci Rep       Date:  2021-09-15       Impact factor: 4.996

2.  A stochastic model for electron multiplication charge-coupled devices--from theory to practice.

Authors:  Michael Hirsch; Richard J Wareham; Marisa L Martin-Fernandez; Michael P Hobson; Daniel J Rolfe
Journal:  PLoS One       Date:  2013-01-31       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.