Literature DB >> 21751359

Ultrasensitive detection of ferritin in human serum by Western blotting based on quantum dots-labeled avidin-biotin system.

Pingping Liu1, Na Na, Tingting Liu, Lingyun Huang, Dacheng He, Wenhao Hua, Jin Ouyang.   

Abstract

Various methods have been applied for serum ferritin detection, however, these methods still have some limitations. Over the last few years, quantum dots (QDs) have become very attractive for immunoassays because of their enormous potentials in ultrasensitive analysis. In this study, a Western blotting method combined with QDs-labeled avidin-biotin system for detecting human serum ferritin was described. Meanwhile, the traditional diaminobenzidine (DAB)-horseradish peroxidase (HRP) method had been compared with the method. The linearity of this QDs-based Western blotting method was from 0.27 to 1.1 ng, and the quantification limit was 0.27 ng, the sensitivity was up to pictogram values. Real serum samples such as hepatoma, thalassemia patient and normal individual sera were analyzed, the analysis results demonstrated that there was significant difference in the concentrations of ferritin between patients and normal individual serum. Furthermore, the recovery of ferritin from the serum samples of patients ranged from 98.15 to 119.67%, and the RSD (relative standard deviation) ranged from 8.73 to 11.61%, the repeatabilities were well within the acceptable range, which revealed that this method is a stable and reproducible method for detecting serum ferritin and have potential application prospect in clinical laboratory of serum ferritin detection.
Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21751359     DOI: 10.1002/pmic.201000742

Source DB:  PubMed          Journal:  Proteomics        ISSN: 1615-9853            Impact factor:   3.984


  4 in total

1.  Improving the sensitivity of traditional Western blotting via Streptavidin containing Poly-horseradish peroxidase (PolyHRP).

Authors:  Manish Mishra; Shuchita Tiwari; Anita Gunaseelan; Dongyang Li; Bruce D Hammock; Aldrin V Gomes
Journal:  Electrophoresis       Date:  2019-05-09       Impact factor: 3.535

2.  Dual-probe (colorimetric and fluorometric) detection of ferritin using antibody-modified gold@carbon dot nanoconjugates.

Authors:  Eepsita Priyadarshini; Kamla Rawat; Himadri B Bohidar; Paulraj Rajamani
Journal:  Mikrochim Acta       Date:  2019-10-09       Impact factor: 5.833

3.  A Comparative Study for Measuring Serum Ferritin Levels with Three Different Laboratory Methods: Enzyme-Linked Immunosorbent Assay versus Cobas e411 and Cobas Integra 400 Methods.

Authors:  Lotfi S Bin Dahman; Khalid M Sumaily; Essa M Sabi; Mohammed A Hassan; Abeer M Bin Thalab; Asrar S Sayad; Saleh M Bin Kolaib; Fatima M Alhadhrmi
Journal:  Diagnostics (Basel)       Date:  2022-01-27

Review 4.  Performance and comparability of laboratory methods for measuring ferritin concentrations in human serum or plasma: A systematic review and meta-analysis.

Authors:  Maria N Garcia-Casal; Juan P Peña-Rosas; Eloisa Urrechaga; Jesus F Escanero; Junsheng Huo; Ricardo X Martinez; Lucero Lopez-Perez
Journal:  PLoS One       Date:  2018-05-03       Impact factor: 3.240