EBT2 radiochromic film for quality assurance of complex IMRT treatments of the prostate: micro-collimated IMRT, RapidArc, and TomoTherapy.

T Kairn1, N Hardcastle, J Kenny, R Meldrum, W A Tomé, T Aland.   

Abstract

In response to the clinical need for a dosimetry system with both high resolution and minimal angular dependence, this study demonstrates the utility of Gafchromic EBT2 radiochromic dosimetry film for the quality assurance of micro-collimated IMRT, RapidArc and TomoTherapy treatments. Firstly, preliminary measurements indicated that the dose response of EBT2 film does not appreciably vary with either the angle of incidence of the radiation beam or the depth in water at which the film is placed. Secondly, prostate treatment plans designed for delivery using static-beam IMRT (collimated using the BrainLab m3 microMLC), RapidArc and TomoTherapy were investigated by comparing dose planes obtained from treatment planning calculations with EBT2 film measurements. For all treatment plans, the proportion of dose points agreeing with the film measurements to within γ (3%,3 mm) was found to be above 95%, with all points agreeing within 5%. The film images provided sufficient information to verify that the treatments could be delivered with an acceptable level of accuracy, while also providing additional information on low-level dose variations that were not predicted by the treatment planning systems. This information included: the location and extent of dose from inter-leaf leakage (in the RapidArc plan) and helical field junctioning (in the TomoTherapy plan), as well as the existence of small regions where the treatment planning system under-predicted the dose from very small treatment segments (in the micro-collimated IMRT plan).

Entities:  

Mesh:

Year:  2011        PMID: 21748444     DOI: 10.1007/s13246-011-0087-z

Source DB:  PubMed          Journal:  Australas Phys Eng Sci Med        ISSN: 0158-9938            Impact factor:   1.430


  9 in total

1.  Designing and Dosimetry of a Shield for Photon Fields of Radiation Therapy in Oral Cavity Cancer.

Authors:  Keyvan Jabbari; Somayeh Senobari; Mahnaz Roayaei; Masoumeh Rostampour
Journal:  J Med Signals Sens       Date:  2015 Apr-Jun

2.  A study on comparison of Gafchromic EBT2 film response under single and cumulative exposure conditions.

Authors:  K Ganapathy; P G G Kurup; V Murali; M Muthukumaran; J Velmurugan
Journal:  J Med Phys       Date:  2013-10

3.  Accuracy and sensitivity of four-dimensional dose calculation to systematic motion variability in stereotatic body radiotherapy (SBRT) for lung cancer.

Authors:  Mark K H Chan; Dora L W Kwong; Sherry C Y Ng; Anthony S M Tong; Eric K W Tam
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

4.  Simplified method for creating a density-absorbed dose calibration curve for the low dose range from Gafchromic EBT3 film.

Authors:  Tatsuhiro Gotanda; Toshizo Katsuda; Rumi Gotanda; Tadao Kuwano; Takuya Akagawa; Nobuyoshi Tanki; Akihiko Tabuchi; Tetsunori Shimono; Yasuyuki Kawaji
Journal:  J Med Phys       Date:  2016 Oct-Dec

5.  Comparative evaluation of modern dosimetry techniques near low- and high-density heterogeneities.

Authors:  Eyad A Alhakeem; Sami AlShaikh; Anatoly B Rosenfeld; Sergei F Zavgorodni
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

6.  Methodology for radiochromic film analysis using FilmQA Pro and ImageJ.

Authors:  Michelle E Howard; Michael G Herman; Michael P Grams
Journal:  PLoS One       Date:  2020-05-21       Impact factor: 3.240

7.  Effect of scanner lens on lateral response artefact in radiochromic film dosimetry.

Authors:  Tarafder Shameem; Nick Bennie; Martin Butson; David Thwaites
Journal:  Phys Eng Sci Med       Date:  2022-05-30

8.  A study of surface dosimetry for breast cancer radiotherapy treatments using Gafchromic EBT2 film.

Authors:  Masahiro Nakano; Robin F Hill; May Whitaker; Jung-Ha Kim; Zdenka Kuncic
Journal:  J Appl Clin Med Phys       Date:  2012-05-10       Impact factor: 2.102

9.  Robotic radiosurgery system patient-specific QA for extracranial treatments using the planar ion chamber array and the cylindrical diode array.

Authors:  Mu-Han Lin; Iavor Veltchev; Sion Koren; Charlie Ma; Jinsgeng Li
Journal:  J Appl Clin Med Phys       Date:  2015-07-08       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.