The influence of platform switching on the biomechanical aspects of the implant-abutment system. A three dimensional finite element study.

Luigi Canullo1, Francesco Pace, Paulo Coelho, Enrico Sciubba, Iole Vozza.   

Abstract

OBJECTIVE: To evaluate the biomechanical scenario of platform switching geometric implant-abutment configuration relative to standard configurations by means of finite element analysis. STUDY
DESIGN: A 3D Finite Element Analysis (FEA) was performed on 3 different implant-abutment configurations: a 3.8 mm implant with a matching diameter abutment (Standard Control Design, SCD), a 5.5 mm implant with matching diameter abutment (Wider Control Design, WCD), and a 5.5mm implant with a 3.8 mm abutment (Experimental Design, ED). All the different experimental groups were discretized to over 60000 elements and 100000 nodes, and 130N vertical (axial) and 90N horizontal loads were applied on the coronal portion of the abutment. Von Mises stresses were evaluated and maximum and minimum values were acquired for each implant-abutment configuration.
RESULTS: The load-induced Von Mises stress (maximum to minumum ranges) on the implant ranged from 150 MPa to 58 Pa (SCD); 45 MPa to 55 Pa (WCD); 190 MPa to 64 Pa (ED). The Von Mises stress on the abutment ranged from 150 MPa to 52 MPa (SCD); 70 MPa to 55 MPa (WCD), and 85 MPa to 42 MPa respectively (ED). The maximum stresses transmitted from the implant-abutment system to the cortical and trabecular bone were 67 Pa and 52 MPa (SCD); 54 Pa and 27 MPa (WCD); 64 Pa and 42 MPa (ED), respectively. When the implant body was evaluated for stresses, a substantial decrease in their levels were observed at the threaded implant region due to the diametral mismatch between implant and abutment for the ED configuration.
CONCLUSION: The platform switching configuration led to not only to a relative decrease in stress levels compared to narrow and wide standard configurations, but also to a notable stress field shift from bone towards the implant system, potentially resulting in lower crestal bone overloading.

Entities:  

Mesh:

Year:  2011        PMID: 21743409     DOI: 10.4317/medoral.17243

Source DB:  PubMed          Journal:  Med Oral Patol Oral Cir Bucal        ISSN: 1698-4447


  10 in total

1.  Stress and strain distribution in three different mini dental implant designs using in implant retained overdenture: a finite element analysis study.

Authors:  W Aunmeungtong; P Khongkhunthian; P Rungsiyakull
Journal:  Oral Implantol (Rome)       Date:  2016-11-16

2.  Platform switching vs standard implants in partially edentulous patients using the Dental Tech Implant System: clinical and radiological results from a prospective multicenter study.

Authors:  Massimo Del Fabbro; Carlo Bianchessi; Riccardo Del Lupo; Luca Landi; Silvio Taschieri; Stefano Corbella
Journal:  Clin Oral Investig       Date:  2015-03-31       Impact factor: 3.573

3.  [The expressions of the Notch and Wnt signaling pathways and their significance in the repair process of alveolar bone defects in rabbits with bone marrow stem cells compounded with platelet-rich fibrin].

Authors:  Chunmei Zhou; Shuhui Li; Naikuli Wenqiguli; Li Yu; Lu Zhao; Peiling Wu; Tuerxun Nijiati
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2016-04

4.  Platform switching on wide-diameter external hex implants: a finite element analysis.

Authors:  Stefano Sivolella; Riccardo Guazzo; Eriberto Bressan; Mario Berengo; Edoardo Stellini
Journal:  J Clin Exp Dent       Date:  2013-04-01

5.  Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system.

Authors:  Jonas Lorenz; Henriette Lerner; Robert A Sader; Shahram Ghanaati
Journal:  Int J Implant Dent       Date:  2017-09-05

6.  Peri-implant marginal bone loss reduction with platform-switching components: 5-Year post-loading results of an equivalence randomized clinical trial.

Authors:  Ana Messias; Salomão Rocha; Wilfried Wagner; Jörg Wiltfang; Maximilian Moergel; Eleonore Behrens; Pedro Nicolau; Fernando Guerra
Journal:  J Clin Periodontol       Date:  2019-06       Impact factor: 8.728

7.  A Three-Dimensional Finite Element Analysis: Maxillary Dentition Distalization with the Aid of Microimplant in Lingual Orthodontics.

Authors:  Xin He; Wei-Hang Zhuang; Dong-Liang Zhang
Journal:  Int J Gen Med       Date:  2021-11-18

8.  Current results and trends in platform switching.

Authors:  Hadi Salimi; Omid Savabi; Farahnaz Nejatidanesh
Journal:  Dent Res J (Isfahan)       Date:  2011-12

9.  Effect of platform switching on the peri-implant bone: A finite element study.

Authors:  Kheira Bouazza-Juanes; Amparo Martínez-González; Germán Peiró; Juan-José Ródenas; María-Victoria López-Mollá
Journal:  J Clin Exp Dent       Date:  2015-10-01

10.  Effect of platform switching on crestal bone levels around implants in the posterior mandible: 3 years results from a multicentre randomized clinical trial.

Authors:  Salomão Rocha; Wilfried Wagner; Jörg Wiltfang; Pedro Nicolau; Maximilian Moergel; Ana Messias; Eleonore Behrens; Fernando Guerra
Journal:  J Clin Periodontol       Date:  2016-03-30       Impact factor: 8.728

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.