Literature DB >> 21742414

Evaluation of different methods to recover meticillin-resistant Staphylococcus aureus from hospital environmental surfaces.

A Dolan1, M Bartlett, B McEntee, E Creamer, H Humphreys.   

Abstract

The environment is implicated as a source of healthcare-associated infections (HAIs) and there is a need for evidence-based approaches to environmental sampling to assess cleanliness and improve infection prevention and control. We assessed, in vitro, different approaches to sampling the environment for meticillin-resistant Staphylococcus aureus (MRSA). In a laboratory-based investigation, the recovery of MRSA from two common hospital environments using six different sampling methods was evaluated, with a wild-type strain of MRSA. A 100 cm(2) section of mattress and a laboratory bench surface were contaminated with known inocula of MRSA. Bacteria were recovered by sampling at 30 min after inoculation, using either saline-moistened cotton swabs, neutralising buffer swabs, eSwabs or macrofoam swabs, which were all enriched in tryptone soya broth, or by sampling with direct contact plates or chromogenic 'sweep' plates. The sensitivity (i.e. the minimum number of bacteria inoculated on to a surface which subsequently produced a positive result) of each method was determined for each surface. The most sensitive methods were eSwabs and macrofoam swabs, requiring 6.1 × 10(-1) and 3.9 × 10(-1) MRSA/cm(2), respectively, to produce a positive result from the bench surface. The least sensitive swabbing method was saline-moistened cotton swabs, requiring 1.1 × 10(3) MRSA/cm(2) of mattress. The recovery of bacteria from environmental samples varies with the swabs and methodology used and negative culture results do not exclude a pathogen-free environment. Greater standardisation is required to facilitate the assessment of cleanliness of healthcare environments.
Copyright © 2011 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21742414     DOI: 10.1016/j.jhin.2011.05.011

Source DB:  PubMed          Journal:  J Hosp Infect        ISSN: 0195-6701            Impact factor:   3.926


  11 in total

1.  Antimicrobial Susceptibility and Enterotoxin-Encoding Genes in Staphylococcus spp. Recovered from Kitchen Equipment from a University Hospital in Rio de Janeiro, Brazil.

Authors:  Roberta Fontanive Miyahira; Emanoella Araújo Santos; Robson Souza Leão; Angela Corrêa de Freitas-Almeida; Mara Lucia Queiroz
Journal:  Microb Drug Resist       Date:  2018-03-20       Impact factor: 3.431

2.  Evaluation of Environmental Sampling Methods for Detection of Staphylococcus aureus on Fomites.

Authors:  Patrick G Hogan; Carey-Ann D Burnham; Lauren N Singh; Carol E Patrick; J Christian Lukas; Jeffrey W Wang; Victoria J Fraser; Stephanie A Fritz
Journal:  Ann Public Health Res       Date:  2015-01-29

3.  Environmental contamination by carbapenem-resistant Enterobacteriaceae.

Authors:  A Lerner; A Adler; J Abu-Hanna; I Meitus; S Navon-Venezia; Y Carmeli
Journal:  J Clin Microbiol       Date:  2012-10-31       Impact factor: 5.948

4.  ATP bioluminescence values are significantly different depending upon material surface properties of the sampling location in hospitals.

Authors:  Tomoko Shimoda; Rika Yano; Shinji Nakamura; Mitsutaka Yoshida; Junji Matsuo; Sadako Yoshimura; Hiroyuki Yamaguchi
Journal:  BMC Res Notes       Date:  2015-12-21

5.  Elevator buttons as unrecognized sources of bacterial colonization in hospitals.

Authors:  Christopher E Kandel; Andrew E Simor; Donald A Redelmeier
Journal:  Open Med       Date:  2014-07-08

6.  A prospective study to examine the epidemiology of methicillin-resistant Staphylococcus aureus and Clostridium difficile contamination in the general environment of three community hospitals in southern Ontario, Canada.

Authors:  Meredith C Faires; David L Pearl; William A Ciccotelli; Karen Straus; Giovanna Zinken; Olaf Berke; Richard J Reid-Smith; J Scott Weese
Journal:  BMC Infect Dis       Date:  2012-11-08       Impact factor: 3.090

7.  Methicillin-resistant Staphylococcus aureus (MRSA) contamination in bedside surfaces of a hospital ward and the potential effectiveness of enhanced disinfection with an antimicrobial polymer surfactant.

Authors:  John W M Yuen; Terence W K Chung; Alice Y Loke
Journal:  Int J Environ Res Public Health       Date:  2015-03-11       Impact factor: 3.390

8.  Visualization of hospital cleanliness in three Japanese hospitals with a tendency toward long-term care.

Authors:  Reina Watanabe; Tomoko Shimoda; Rika Yano; Yasuhiro Hayashi; Shinji Nakamura; Junji Matsuo; Hiroyuki Yamaguchi
Journal:  BMC Res Notes       Date:  2014-03-04

9.  Utilizing Moist or Dry Swabs for the Sampling of Nasal MRSA Carriers? An In Vivo and In Vitro Study.

Authors:  Philipp Warnke; Annette Devide; Mirjam Weise; Hagen Frickmann; Norbert Georg Schwarz; Holger Schäffler; Peter Ottl; Andreas Podbielski
Journal:  PLoS One       Date:  2016-09-14       Impact factor: 3.240

10.  Evaluation of Methods for Sampling of Staphylococcus aureus and Other Staphylococcus Species from Indoor Surfaces.

Authors:  Anne Mette Madsen; Hoang U T Phan; Mathias Laursen; John K White; Katrine Uhrbrand
Journal:  Ann Work Expo Health       Date:  2020-11-16       Impact factor: 2.179

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.