Literature DB >> 21741951

Calibration of nanowatt isothermal titration calorimeters with overflow reaction vessels.

Neil A Demarse1, Colette F Quinn, Dennis L Eggett, Donald J Russell, Lee D Hansen.   

Abstract

Obtaining accurate results with nanowatt titration calorimeters with overflow cells requires mass calibration of the buret injection volume, chemical calibration of the reaction vessel effective volume, and chemical calibration of the calorimetric factor used to convert the measured electrical signal to heat rate. Potential errors in electrical calibration of power compensation calorimeters require validation of the calorimetric factor with chemical reactions with accurately known stoichiometries and enthalpy changes. The effective volume of the reaction vessel can be determined from the endpoint of a quantitative reaction with known stoichiometries. Methods for calibration and potential calibration errors to be avoided are described. Publication of results obtained must include data on calibrations and sufficient raw data to assess precision and accuracy of the results.
Copyright © 2011 Elsevier Inc. All rights reserved.

Mesh:

Year:  2011        PMID: 21741951     DOI: 10.1016/j.ab.2011.06.014

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  10 in total

1.  An explicit formulation approach for the analysis of calcium binding to EF-hand proteins using isothermal titration calorimetry.

Authors:  Camille Keeler; Gregory Poon; Ivana Y Kuo; Barbara E Ehrlich; Michael E Hodsdon
Journal:  Biophys J       Date:  2013-12-17       Impact factor: 4.033

2.  Cross-platform comparison of nucleic acid hybridization: toward quantitative reference standards.

Authors:  Ken Halvorsen; Paul F Agris
Journal:  Anal Biochem       Date:  2014-08-12       Impact factor: 3.365

3.  Obtaining precise and accurate results by ITC.

Authors:  Lee D Hansen; Colette Quinn
Journal:  Eur Biophys J       Date:  2019-09-25       Impact factor: 1.733

4.  Fitting two- and three-site binding models to isothermal titration calorimetric data.

Authors:  Chad A Brautigam
Journal:  Methods       Date:  2014-12-05       Impact factor: 3.608

5.  Palmitic acid is a toll-like receptor 4 ligand that induces human dendritic cell secretion of IL-1β.

Authors:  Dequina A Nicholas; Kangling Zhang; Christopher Hung; Shane Glasgow; Aruni Wilson Aruni; Juli Unternaehrer; Kimberly J Payne; William H R Langridge; Marino De Leon
Journal:  PLoS One       Date:  2017-05-02       Impact factor: 3.240

6.  Multi-site binding of epigallocatechin gallate to human serum albumin measured by NMR and isothermal titration calorimetry.

Authors:  Joshua D Eaton; Mike P Williamson
Journal:  Biosci Rep       Date:  2017-05-11       Impact factor: 3.840

7.  Estimation of non-constant variance in isothermal titration calorimetry using an ITC measurement model.

Authors:  Xiujie Ge; Lan Chen; Dexing Li; Renxiao Liu; Guanglu Ge
Journal:  PLoS One       Date:  2020-12-30       Impact factor: 3.240

8.  Potential natural products that target the SARS-CoV-2 spike protein identified by structure-based virtual screening, isothermal titration calorimetry and lentivirus particles pseudotyped (Vpp) infection assay.

Authors:  Guan-Yu Chen; Yi-Cheng Pan; Tung-Ying Wu; Tsung-You Yao; Wei-Jan Wang; Wan-Jou Shen; Azaj Ahmed; Shu-Ting Chan; Chih-Hsin Tang; Wei-Chien Huang; Mien-Chie Hung; Juan-Cheng Yang; Yang-Chang Wu
Journal:  J Tradit Complement Med       Date:  2021-09-16

9.  Thermodynamic Swings: How Ideal Complex of Cas9-RNA/DNA Forms.

Authors:  Polina V Zhdanova; Alexander A Lomzov; Daria V Prokhorova; Grigory A Stepanov; Alexander A Chernonosov; Vladimir V Koval
Journal:  Int J Mol Sci       Date:  2022-08-10       Impact factor: 6.208

Review 10.  Enzyme Kinetics by Isothermal Titration Calorimetry: Allostery, Inhibition, and Dynamics.

Authors:  Yun Wang; Guanyu Wang; Nicolas Moitessier; Anthony K Mittermaier
Journal:  Front Mol Biosci       Date:  2020-10-19
  10 in total