Literature DB >> 21741817

Pulse-driven magnetoimpedance sensor detection of biomagnetic fields in musculatures with spontaneous electric activity.

Shinsuke Nakayama1, Satoshi Atsuta, Takao Shinmi, Tsuyoshi Uchiyama.   

Abstract

We measured biomagnetic fields in musculatures with spontaneous electric activity using a pulse-driven magnetoimpedance (PMI) sensor with the sensitivity improved toward a pico-Tesla (pT) level. Due to the sufficiently short operation interval of 1 μs, this magnetic sensor enabled quasi-real time recordings of the magnetic field for biological electric activity. Isolated small musculatures from the guinea-pig stomach, taenia caeci, portal vein and urinary bladder were incubated in an organ bath at a body temperature. The improved PMI sensor mounted approximately 1mm below the preparations detected oscillatory magnetic fields reflecting spontaneous electric activities of musculature preparations. In the taenia caeci, application of tetraethyl ammonium (TEA), a K(+) channel blocker, significantly enhanced the magnetic activity estimated by histogram analysis. Also, in some musculature preparations, simultaneous measurements with electric activity revealed that the observed magnetic activities were attributed to biological electric activity. PMI technology is promising for applications in biology and medicine.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21741817     DOI: 10.1016/j.bios.2011.05.041

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  8 in total

1.  A possible association between space weather conditions and the risk of acute coronary syndrome in patients with diabetes and the metabolic syndrome.

Authors:  Jone Vencloviene; Ruta Marija Babarskiene; Deivydas Kiznys
Journal:  Int J Biometeorol       Date:  2016-06-25       Impact factor: 3.787

2.  Pulse-driven magnetoimpedance sensor detection of cardiac magnetic activity.

Authors:  Shinsuke Nakayama; Kenta Sawamura; Kaneo Mohri; Tsuyoshi Uchiyama
Journal:  PLoS One       Date:  2011-10-12       Impact factor: 3.240

3.  Serotonin augments gut pacemaker activity via 5-HT3 receptors.

Authors:  Hong-Nian Liu; Susumu Ohya; Yuji Nishizawa; Kenta Sawamura; Satoshi Iino; Mohsin Md Syed; Kazunori Goto; Yuji Imaizumi; Shinsuke Nakayama
Journal:  PLoS One       Date:  2011-09-15       Impact factor: 3.240

4.  Spatial analysis of slowly oscillating electric activity in the gut of mice using low impedance arrayed microelectrodes.

Authors:  Mizuki Taniguchi; Shunichi Kajioka; Habibul B Shozib; Kenta Sawamura; Shinsuke Nakayama
Journal:  PLoS One       Date:  2013-10-04       Impact factor: 3.240

5.  Real-time measurement of biomagnetic vector fields in functional syncytium using amorphous metal.

Authors:  Shinsuke Nakayama; Tusyoshi Uchiyama
Journal:  Sci Rep       Date:  2015-03-06       Impact factor: 4.379

6.  PT-Level High-Sensitivity Magnetic Sensor with Amorphous Wire.

Authors:  Dongfeng He
Journal:  Sensors (Basel)       Date:  2019-12-26       Impact factor: 3.576

7.  Magnetic sensors using amorphous metal materials: detection of premature ventricular magnetic waves.

Authors:  Tsuyoshi Uchiyama; Shinsuke Nakayama
Journal:  Physiol Rep       Date:  2013-07-21

8.  A magnetic sensor with amorphous wire.

Authors:  Dongfeng He; Mitsuharu Shiwa
Journal:  Sensors (Basel)       Date:  2014-06-17       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.