Literature DB >> 21741509

Protection of stapled colorectal anastomoses with a biodegradable device: the C-Seal feasibility study.

Joe L Kolkert1, Klaas Havenga, Henk O ten Cate Hoedemaker, Johan Zuidema, Rutger J Ploeg.   

Abstract

BACKGROUND: A colorectal anastomotic leak can be life-threatening. We have assessed the feasibility of a new intraluminal biodegradable bypass device that we designed to avoid anastomotic leakage and the necessity of a temporary stoma.
METHODS: Fifteen patients underwent colorectal surgery. Before performing the anastomosis in a standard way, the C-Seal (Polyganics BV, Groningen, The Netherlands) was glued to the anvil of the circular stapler. Consequently, the bypass was fixated in the staple row just proximal of the simultaneously made anastomosis. A water-soluble contrast enema was performed after 1 week.
RESULTS: The sheath was well compatible with the standard stapler device and easy to use. All donuts remained intact. No radiologic or clinical leaks were observed after surgery.
CONCLUSIONS: This pilot study shows that the C-Seal can be applied successfully in colorectal surgery. Further investigation with large numbers of patients is now necessary to assess the efficacy of the C-Seal as a protective device.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21741509     DOI: 10.1016/j.amjsurg.2010.04.014

Source DB:  PubMed          Journal:  Am J Surg        ISSN: 0002-9610            Impact factor:   2.565


  8 in total

1.  Sutureless primary repair of colonic perforation with a degradable stent in a porcine model of fecal peritonitis.

Authors:  Kun Liu; Hong Yu; Minghui Zhang; Yichen Yu; Yifan Wang; Xiujun Cai
Journal:  Int J Colorectal Dis       Date:  2012-06-05       Impact factor: 2.571

Review 2.  Emerging Trends in the Etiology, Prevention, and Treatment of Gastrointestinal Anastomotic Leakage.

Authors:  Sami A Chadi; Abe Fingerhut; Mariana Berho; Steven R DeMeester; James W Fleshman; Neil H Hyman; David A Margolin; Joseph E Martz; Elisabeth C McLemore; Daniela Molena; Martin I Newman; Janice F Rafferty; Bashar Safar; Anthony J Senagore; Oded Zmora; Steven D Wexner
Journal:  J Gastrointest Surg       Date:  2016-09-16       Impact factor: 3.452

Review 3.  Can intraluminal devices prevent or reduce colorectal anastomotic leakage: a review.

Authors:  Annelien N Morks; Klaas Havenga; Rutger J Ploeg
Journal:  World J Gastroenterol       Date:  2011-10-28       Impact factor: 5.742

4.  The C-seal: a biofragmentable drain protecting the stapled colorectal anastomosis from leakage.

Authors:  Annelien N Morks; Klaas Havenga; Henk O Ten Cate Hoedemaker; Rutger J Ploeg
Journal:  J Vis Exp       Date:  2010-11-04       Impact factor: 1.355

5.  The C-seal trial: colorectal anastomosis protected by a biodegradable drain fixed to the anastomosis by a circular stapler, a multi-center randomized controlled trial.

Authors:  Ilsalien S Bakker; Annelien N Morks; Henk O Ten Cate Hoedemaker; Johannes G M Burgerhof; Henri G Leuvenink; Rutger J Ploeg; Klaas Havenga
Journal:  BMC Surg       Date:  2012-11-15       Impact factor: 2.102

6.  Thirty-seven patients treated with the C-seal: protection of stapled colorectal anastomoses with a biodegradable sheath.

Authors:  Annelien N Morks; Klaas Havenga; Henk O ten Cate Hoedemaker; Jeroen W A Leijtens; Rutger J Ploeg
Journal:  Int J Colorectal Dis       Date:  2013-06-14       Impact factor: 2.571

7.  Prevention of anastomotic fistula formation after low-position Dixon Operation.

Authors:  Feng Gao; Ming Xu; Feng Song; Xin Zhang; Yong Zhao
Journal:  Pak J Med Sci       Date:  2014-09       Impact factor: 1.088

8.  In vitro degradation profiles and in vivo biomaterial-tissue interactions of microwell array delivery devices.

Authors:  Elahe Hadavi; Rick H W de Vries; Alexandra M Smink; Bart de Haan; Jeroen Leijten; Leendert W Schwab; Marcel H B J Karperien; Paul de Vos; Pieter J Dijkstra; Aart A van Apeldoorn
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2020-07-16       Impact factor: 3.368