Literature DB >> 21741209

Ultrasound intima-media segmentation using Hough transform and dual snake model.

Xiangyang Xu1, Yuan Zhou, Xinyao Cheng, Enmin Song, Guokuan Li.   

Abstract

Common carotid artery intima-media thickness (IMT), which is usually measured upon ultrasound images, is an important indicator to cardiovascular diseases. This paper proposes a snake model based segmentation method to automatically detect the boundary of intima-media for IMT measurement. In the proposed method, two contours are initialized from line segments generated by Hough transform and then evolved simultaneously by dual snake model for boundary detection. Experimental results show that the proposed method has strong robustness against ultrasound artifacts, gives better results than traditional snake model and dynamic programming based methods, and achieves similar clinical parameters to ground truth data. Copyright Â
© 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21741209     DOI: 10.1016/j.compmedimag.2011.06.007

Source DB:  PubMed          Journal:  Comput Med Imaging Graph        ISSN: 0895-6111            Impact factor:   4.790


  6 in total

1.  Robust segmentation and intelligent decision system for cerebrovascular disease.

Authors:  Asmatullah Chaudhry; Mehdi Hassan; Asifullah Khan
Journal:  Med Biol Eng Comput       Date:  2016-04-07       Impact factor: 2.602

2.  Automatic detection of the intima-media thickness in ultrasound images of the common carotid artery using neural networks.

Authors:  Rosa-María Menchón-Lara; María-Consuelo Bastida-Jumilla; Juan Morales-Sánchez; José-Luis Sancho-Gómez
Journal:  Med Biol Eng Comput       Date:  2013-11-27       Impact factor: 2.602

3.  A review of ultrasound common carotid artery image and video segmentation techniques.

Authors:  Christos P Loizou
Journal:  Med Biol Eng Comput       Date:  2014-10-05       Impact factor: 2.602

Review 4.  Carotid artery segmentation in ultrasound images and measurement of intima-media thickness.

Authors:  Vaishali Naik; R S Gamad; P P Bansod
Journal:  Biomed Res Int       Date:  2013-06-20       Impact factor: 3.411

5.  An improved approach for accurate and efficient measurement of common carotid artery intima-media thickness in ultrasound images.

Authors:  Qiang Li; Wei Zhang; Xin Guan; Yu Bai; Jing Jia
Journal:  Biomed Res Int       Date:  2014-08-18       Impact factor: 3.411

6.  Good and bad boundaries in ultrasound compounding: preserving anatomic boundaries while suppressing artifacts.

Authors:  Alex Ling Yu Hung; John Galeotti
Journal:  Int J Comput Assist Radiol Surg       Date:  2021-08-06       Impact factor: 2.924

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.