Sleep and daytime sleepiness of patients with left ventricular assist devices: a longitudinal pilot study.

Jesus M Casida1, Jean E Davis, Robert J Brewer, Cheryl Smith, Hossein Yarandi.   

Abstract

CONTEXT: No empirical longitudinal data on sleep and daytime sleepiness patterns in patients with an implantable left ventricular assist device (LVAD) exist.
OBJECTIVE: (1) To describe the sleep patterns (sleep onset latency, sleep efficiency, sleep fragmentation index, total sleep time, and wake after sleep onset), sleep quality, and daytime sleepiness variables and (2) to determine the change in the pattern of these variables before and up to 6 months after LVAD implantation.
DESIGN: A longitudinal descriptive repeated-measures design was used. Patients wore wrist actigraphs (AW64 Actiwatch), which objectively measured sleep, for 3 consecutive days and nights before LVAD implant and at the first and second week and first, third, and sixth month after implantation. During these periods, patients also completed questionnaires on sleep quality and daytime sleepiness. Patients-Twelve of 15 patients completed the 6-month data. Data were analyzed by using descriptive statistics and repeated-measures analysis of variance.
RESULTS: We found long sleep onset latencies and low sleep efficiency across time periods. High sleep fragmentation index was noted at baseline and 1 week after LVAD. Short total sleep times, long wake-after-sleep-onset durations, and poor sleep quality were evident at baseline and persisted up to 6 months after LVAD implantation. Low alertness level, a manifestation of sleepiness, was common during late morning to early evening hours. However, only sleep efficiency and wake after sleep onset showed significant changes in pattern (P < .05).
CONCLUSION: Sleep disturbance and daytime sleepiness may be prevalent before and up to 6 months after LVAD implantation, warranting further investigation.

Entities:  

Mesh:

Year:  2011        PMID: 21736242     DOI: 10.1177/152692481102100208

Source DB:  PubMed          Journal:  Prog Transplant        ISSN: 1526-9248            Impact factor:   1.065


  5 in total

1.  Implant Strategy-Specific Changes in Symptoms in Response to Left Ventricular Assist Devices.

Authors:  Christopher S Lee; Jill M Gelow; Christopher V Chien; Shirin O Hiatt; Julie T Bidwell; Quin E Denfeld; Kathleen L Grady; James O Mudd
Journal:  J Cardiovasc Nurs       Date:  2018 Mar/Apr       Impact factor: 2.083

2.  Sleep and self-care correlates before and after implantation of a left-ventricular assist device (LVAD).

Authors:  Jesus M Casida; Jean E Davis; Francis D Pagani; James E Aikens; Celeste Williams; James J Yang
Journal:  J Artif Organs       Date:  2018-04-13       Impact factor: 1.731

Review 3.  Psychosocial factors and quality-of-life after heart transplantation and mechanical circulatory support.

Authors:  Emily M Rosenberger; Kristen R Fox; Andrea F DiMartini; Mary Amanda Dew
Journal:  Curr Opin Organ Transplant       Date:  2012-10       Impact factor: 2.640

Review 4.  Actigraphy for measurement of sleep and sleep-wake rhythms in relation to surgery.

Authors:  Michael T Madsen; Jacob Rosenberg; Ismail Gögenur
Journal:  J Clin Sleep Med       Date:  2013-04-15       Impact factor: 4.062

5.  A review of ethical considerations for ventricular assist device placement in older adults.

Authors:  Courtenay R Bruce
Journal:  Aging Dis       Date:  2013-01-18       Impact factor: 6.745