Literature DB >> 21735535

3-D guidance of complex pulmonary artery stent placement using reconstructed rotational angiography with live overlay.

Thomas Fagan1, Joseph Kay, John Carroll, Anne Neubauer.   

Abstract

Technologies which allow rotational angiographic image acquisition and three dimensional (3-D) vascular reconstruction with subsequent fluoroscopic registration for live 3-D image overlay are rapidly being adopted. We present the first use of rotational angiography with integrated 3-D image overlay for guidance during complex pulmonary artery stent placement. Technical considerations, advantages, and limitations of this procedural strategy are discussed.
Copyright © 2011 Wiley-Liss, Inc.

Mesh:

Substances:

Year:  2011        PMID: 21735535     DOI: 10.1002/ccd.23229

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  15 in total

1.  Case Report: Percutaneous Closure of an Ascending Aortic Pseudoaneurysm by 3D Angiography Guidance.

Authors:  C Huie Lin; Joshua Murphy; David T Balzer
Journal:  Methodist Debakey Cardiovasc J       Date:  2015 Apr-Jun

2.  Three-Dimensional Rotational Angiography in the Pediatric Cath Lab: Optimizing Aortic Interventions.

Authors:  Anna Stenger; Sven Dittrich; Martin Glöckler
Journal:  Pediatr Cardiol       Date:  2015-12-14       Impact factor: 1.655

3.  Diagnostic Utility of Three-Dimensional Rotational Angiography in Congenital Cardiac Catheterization.

Authors:  Osamah Aldoss; Brian M Fonseca; Uyen T Truong; John Bracken; Jeffrey R Darst; Ruixin Guo; Tamekia L Jones; Thomas E Fagan
Journal:  Pediatr Cardiol       Date:  2016-06-09       Impact factor: 1.655

4.  Clinical manifestations and long-term follow-up in pediatric patients living at altitude with isolated pulmonary artery of ductal origin.

Authors:  Shinichi Takatsuki; Jeffrey R Darst; Bibhuti B Das; Thomas E Fagan; Robert Wolfe; David Dunbar Ivy
Journal:  Pediatr Cardiol       Date:  2012-03-20       Impact factor: 1.655

Review 5.  Multimodality 3-dimensional image integration for congenital cardiac catheterization.

Authors:  Thomas E Fagan; Uyen T Truong; Pei-Ni Jone; John Bracken; Robert Quaife; Anas A Abu Hazeem; Ernesto E Salcedo; Brian M Fonseca
Journal:  Methodist Debakey Cardiovasc J       Date:  2014 Apr-Jun

6.  Optimizing 3D Rotational Angiography for Congenital Cardiac Catheterization.

Authors:  Arash Salavitabar; Brian A Boe; Darren P Berman; Andrew Harrison; Jason Swinning; Kristine Baptista; Mariah Eisner; Shasha Bai; Aimee K Armstrong
Journal:  Pediatr Cardiol       Date:  2022-08-27       Impact factor: 1.838

7.  Radiation Exposure by Three-Dimensional Rotational Angiography (3DRA) During Trans-catheter Melody Pulmonary Valve Procedures (TMPV) in a Pediatric Cardiac Catheterization Laboratory.

Authors:  Hoang H Nguyen; David T Balzer; Joshua J Murphy; Ramzi Nicolas; Shabana Shahanavaz
Journal:  Pediatr Cardiol       Date:  2016-07-25       Impact factor: 1.655

Review 8.  Multimodality Imaging in Congenital Heart Disease: an Update.

Authors:  Uyen T Truong; Shelby Kutty; Craig S Broberg; David J Sahn
Journal:  Curr Cardiovasc Imaging Rep       Date:  2012

9.  Value of Image Fusion in Coronary Angiography for the Detection of Coronary Artery Bypass Grafts.

Authors:  Julien Plessis; Karine Warin Fresse; Zachary Cahouch; Thibaut Manigold; Vincent Letocart; Laurianne Le Gloan; Béatrice Guyomarch; Patrice Guerin
Journal:  J Am Heart Assoc       Date:  2016-06-10       Impact factor: 5.501

10.  Early experience with the Venus p‑valve for percutaneous pulmonary valve implantation in native outflow tract.

Authors:  F Garay; X Pan; Y J Zhang; C Wang; D Springmuller
Journal:  Neth Heart J       Date:  2017-02       Impact factor: 2.380

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.