Literature DB >> 21735531

Reduced antiplatelet therapy after drug-eluting stenting: multicenter Janus Flex carbostent implantation with short dual antiplatelet treatment for 2 or 6 months-MATRIX study.

Salvatore Cassese1, Giuseppe De Luca, Bruno Villari, Sergio Berti, Pietro Bellone, Alfonso Alfieri, Antonio Montinaro, Gaetano Quaranta, Paolo Marraccini, Federico Piscione.   

Abstract

OBJECTIVES: The Multicentre registry with Antiplatelet TReatment two-sIX months (MATRIX) evaluated safety and efficacy at 12-month follow-up of Janus Flex stenting with 2- or 6-month dual antiplatelet therapy (DAT) period.
BACKGROUND: There are no data of Janus Flex stent (Carbostent and Implantable Devices-CID, Saluggia, Italy), a polymer-free, tacrolimus-eluting coronary stent, followed by short-term DAT, in daily practice.
METHODS: Patients were prospectively enrolled at 12 high-volume procedures centres. After stenting, four sites prescribed 2-month DAT, eight sites 6-month DAT. Major adverse cardiac events (MACE) and stent thrombosis (ST) rate was evaluated at 12-month follow-up, for entire population, as well as for 2- and 6-month DAT groups, distinctly. MACE included cardiac death, myocardial infarction (MI), and target lesion revascularization (TLR).
RESULTS: From March 2007 to June 2008, 572 patients (mean age 64.91 ± 11 years, 77.45% males) were enrolled. After successful stenting, 12-month follow-up showed a 12.74% MACE occurrence (cardiac death 0.98%; MI 3.13%; TLR 8.62%), with good Janus Flex safety profile confirmed by only two (0.39%) ST. After adjustment for potential confounding, no significant differences were noted at 12-month follow-up among 2- or 6-month DAT groups (MACE-8.99% versus 12.47%, P = 0.16; cardiac death-0.54% versus 1.14%, P = 0.52; MI-2.38% versus 2.71%, P = 0.83; TLR-5.66% versus 10.60%, P = 0.20; ST-0% versus 0.55%, P = 0.99). At multivariable analysis, DAT time duration was not an independent risk factor for adverse events (adjusted HR 0.47, 95% confidence interval 0.16-1.35, P = 0.16).
CONCLUSIONS: Janus Flex coronary stenting, followed by short DAT, is safe and feasible, without differences between 2- and 6-month DAT groups. A randomized trial confirming these encouraging data is needed.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21735531     DOI: 10.1002/ccd.23223

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  3 in total

1.  OPTIMA Tacrolimus-eluting Stent: A Twelve-month Clinical Follow up with Two Different Periods of Dual Antiplatelet Therapy; 2-month vs. 6-month Approach.

Authors:  Nasser Aslanabadi; Ahmad Separham; Reza Beheshti; Samad Ghaffari; Bahram Sohrabi
Journal:  J Cardiovasc Thorac Res       Date:  2012-09-23

2.  Early surgery after coronary revascularization: a fine line between bleeding and thrombosis.

Authors:  C De Biase; E Capuano; S De Luca; C D'Anna; R Luciano; F Piscione; B Trimarco; G Galasso
Journal:  Transl Med UniSa       Date:  2014-12-19

Review 3.  Management of atrial fibrillation in patients undergoing percutaneous coronary intervention.

Authors:  M Mirra; M Di Maio; G Vitulano; C Prota; Mv Polito; S Poto; L Pierro; F Piscione
Journal:  Transl Med UniSa       Date:  2014-04-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.