Literature DB >> 21735514

Outcomes of concomitant percutaneous coronary intervention and balloon aortic valvuloplasty.

Itsik Ben-Dor1, Gabriel Maluenda, Patrick M Looser, Petros Okubagzi, Rebecca Torguson, Zhenyi Xue, Joseph Lindsay, Lowell F Satler, Augusto D Pichard, Ron Waksman.   

Abstract

BACKGROUND: Coronary artery disease often coexists with severe aortic stenosis. The feasibility and safety of combined balloon aortic valvuloplasty (BAV) and percutaneous coronary intervention (PCI) are unknown. AIM: To compare outcomes and complications of combined BAV and PCI with BAV alone.
METHODS: The study cohort consisted of 409 patients with severe aortic stenosis undergoing BAV from 1/2007 to 12/2010. Overall, 329 patients underwent BAV alone and 80 underwent concomitant PCI. Clinical and hemodynamic data, as well as acute and intermediate-term outcomes, were collected.
RESULTS: At the operator's discretion PCI was done before BAV in 66 (82.5%) and after in 14 (17.5%). Patients who underwent concomitant procedures had a higher incidence of prior stroke and a lower incidence of atrial fibrillation. Procedure time and fluoroscopic time were significantly greater in the BAV/PCI group, (90.0 ± 36.6 vs. 72.8 ± 39.8, P = 0.002 and 20.5 ± 10.9 vs. 12.9 ± 7.0, P < 0.001). Significantly more radiographic contrast was used in the BAV/PCI group (95.1 ± 45.5 vs. 36.7 ± 38.4 cm(3) , P < 0.001. Serious adverse events occurred with equal frequency 13.7 and 17.3%, P = 0.44). Transfusion requirement was also similar (21.2% vs. 20.0%, P = 0.81). The frequency of a periprocedural increase in troponin or creatinine was also similar. In the BAV alone group the mortality rate was 48.6% (n = 160) during a mean follow-up of 191 days, and in the BAV/PCI group the mortality rate was 40% (n = 32) during mean follow-up of 175.5 day, P = 0.34.
CONCLUSION: Combined BAV and PCI are safe and are associated with similar complications as BAV alone and may offer protection against myocardial ischemia during BAV.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Keywords:  aortic stenosis; percutaneous coronary intervention; valvuloplasty

Mesh:

Substances:

Year:  2013        PMID: 21735514     DOI: 10.1002/ccd.23193

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  2 in total

1.  Percutaneous balloon aortic valvuloplasty in the era of transcatheter aortic valve implantation: a narrative review.

Authors:  Thomas R Keeble; Arif Khokhar; Mohammed Majid Akhtar; Anthony Mathur; Roshan Weerackody; Simon Kennon
Journal:  Open Heart       Date:  2016-12-07

Review 2.  The safety of concomitant transcatheter aortic valve replacement and percutaneous coronary intervention: A systematic review and meta-analysis.

Authors:  Yong Yang; Fang-Yang Huang; Bao-Tao Huang; Tian-Yuan Xiong; Xiao-Bo Pu; Shi-Jian Chen; Mao Chen; Yuan Feng
Journal:  Medicine (Baltimore)       Date:  2017-12       Impact factor: 1.817

  2 in total