Literature DB >> 21728303

Limitation of time-of-flight resolution in the ultra high mass range.

Jeonghoon Lee, Peter T A Reilly.   

Abstract

In this work, we have examined the reason for the deterioration of resolution and mass accuracy of time-of-flight mass analyzers with increasing mass after the expansion-induced kinetic energy has been eliminated by collisional cooling in an ion guide. Theoretically, removing the expansion-induced kinetic energy by collisional cooling permits the ions to travel along the ion guide axes without significant deviation so that they can be injected into the analyzer in a well-collimated ion beam with well-defined kinetic energy. If the ions can be injected into an orthogonal acceleration time-of-flight mass analyzer (oa-TOF) in this manner, high-resolution mass analysis can be obtained regardless of mass or m/z. Unfortunately, high resolution did not result. It is our contention that the effusive expansion out of the first ion guide yields dispersive axial ejection that reduces TOF resolving power with increasing mass not m/z.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21728303      PMCID: PMC3146560          DOI: 10.1021/ac201537b

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  2 in total

1.  A tandem mass spectrometer for improved transmission and analysis of large macromolecular assemblies.

Authors:  Frank Sobott; Helena Hernández; Margaret G McCammon; Mark A Tito; Carol V Robinson
Journal:  Anal Chem       Date:  2002-03-15       Impact factor: 6.986

2.  Collisional cooling of large ions in electrospray mass spectrometry.

Authors:  Igor V Chernushevich; Bruce A Thomson
Journal:  Anal Chem       Date:  2004-03-15       Impact factor: 6.986

  2 in total
  3 in total

1.  Boundaries of mass resolution in native mass spectrometry.

Authors:  Philip Lössl; Joost Snijder; Albert J R Heck
Journal:  J Am Soc Mass Spectrom       Date:  2014-04-04       Impact factor: 3.109

2.  High resolution time-of-flight mass analysis of the entire range of intact singly-charged proteins.

Authors:  Jeonghoon Lee; Huijuan Chen; Tiancheng Liu; Clifford E Berkman; Peter T A Reilly
Journal:  Anal Chem       Date:  2011-11-17       Impact factor: 6.986

Review 3.  Applications and continued evolution of glycan imaging mass spectrometry.

Authors:  Colin T McDowell; Xiaowei Lu; Anand S Mehta; Peggi M Angel; Richard R Drake
Journal:  Mass Spectrom Rev       Date:  2021-08-15       Impact factor: 10.946