Literature DB >> 21727428

Calibration of silicon atomic force microscope cantilevers.

Christopher T Gibson1, D Alastair Smith, Clive J Roberts.   

Abstract

We present a comparison of three different methods to calibrate the spring constant of two different types of silicon beam shaped atomic force microscope (AFM) cantilevers to determine each method's accuracy, ease of use and potential destructiveness. The majority of research in calibrating AFM cantilevers has been concerned with contact mode levers. The two types of levers we have studied are used in force modulation and tapping mode in air. Not only can these types of cantilevers have spring constants an order of magnitude greater than contact mode levers, but also their geometries can be quite different from the standard V-shape contact lever. In this work we experimentally determine the correction factors for two of the calibration methods when applied to the tapping mode cantilevers and also demonstrate that the force modulation levers can be calibrated easily and accurately using these same techniques.

Entities:  

Year:  2005        PMID: 21727428     DOI: 10.1088/0957-4484/16/2/009

Source DB:  PubMed          Journal:  Nanotechnology        ISSN: 0957-4484            Impact factor:   3.874


  7 in total

1.  An investigation into the rheology of pharmaceutical inter-granular material bridges at high shear rates.

Authors:  Barry Crean; Xinyong Chen; Simon R Banks; Walter G Cook; Colin D Melia; Clive J Roberts
Journal:  Pharm Res       Date:  2009-02-03       Impact factor: 4.200

2.  A direct micropipette-based calibration method for atomic force microscope cantilevers.

Authors:  Baoyu Liu; Yan Yu; Da-Kang Yao; Jin-Yu Shao
Journal:  Rev Sci Instrum       Date:  2009-06       Impact factor: 1.523

Review 3.  Viscoelasticity, Like Forces, Plays a Role in Mechanotransduction.

Authors:  Claudia Tanja Mierke
Journal:  Front Cell Dev Biol       Date:  2022-02-09

4.  Nanomechanical properties of α-synuclein amyloid fibrils: a comparative study by nanoindentation, harmonic force microscopy, and Peakforce QNM.

Authors:  Kim Sweers; Kees van der Werf; Martin Bennink; Vinod Subramaniam
Journal:  Nanoscale Res Lett       Date:  2011-03-30       Impact factor: 4.703

5.  Post-Translational Sortase-Mediated Attachment of High-Strength Force Spectroscopy Handles.

Authors:  Ellis Durner; Wolfgang Ott; Michael A Nash; Hermann E Gaub
Journal:  ACS Omega       Date:  2017-06-30

6.  Effective sensor properties and sensitivity considerations of a dynamic co-resonantly coupled cantilever sensor.

Authors:  Julia Körner
Journal:  Beilstein J Nanotechnol       Date:  2018-09-25       Impact factor: 3.649

7.  From genes to protein mechanics on a chip.

Authors:  Marcus Otten; Wolfgang Ott; Markus A Jobst; Lukas F Milles; Tobias Verdorfer; Diana A Pippig; Michael A Nash; Hermann E Gaub
Journal:  Nat Methods       Date:  2014-09-07       Impact factor: 28.547

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.