Literature DB >> 21727413

Force microscopy experiments with ultrasensitive cantilevers.

S Rast1, U Gysin, P Ruff, Ch Gerber, E Meyer, D W Lee.   

Abstract

Force microscopy experiments with the pendulum geometry are performed with attonewton sensitivity (Rugar et al 2004 Nature 43 329). Single-crystalline cantilevers with sub-millinewton spring constants were annealed under ultrahigh-vacuum conditions. It is found that annealing with temperatures below 500 °C can improve the quality factor by an order of magnitude. The high force sensitivity of these ultrasoft cantilevers is used to characterize small magnetic and superconductive particles, which are mounted on the end of the cantilever. Their magnetic properties are analysed in magnetic fields as a function of temperature. The transition of a superconducting sample mounted on a cantilever is measured by the detection of frequency shifts. An increase of dissipation is observed below the critical temperature. The magnetic moment of ferromagnetic particles is determined by real time frequency detection with a phase-locked loop (PLL) as a function of the magnetic field. The dissipation between the probing tip and the sample is another important ingredient for ultrasensitive force measurements. It is found that dissipation increases at separations of 30 nm. The origins of this type of dissipation are poorly understood. However, it is predicted theoretically that adsorbates can increase this dissipation channel (Volokitin and Persson 2005 Phys. Rev. Lett. 94 086104). First experiments are performed under ultrahigh vacuum to investigate this type of dissipation. Long-range dissipation is closely related to long-range forces. The distance dependence of the contact potential is found to be an important aspect.

Year:  2006        PMID: 21727413     DOI: 10.1088/0957-4484/17/7/S15

Source DB:  PubMed          Journal:  Nanotechnology        ISSN: 0957-4484            Impact factor:   3.874


  4 in total

1.  Suppression of electronic friction on Nb films in the superconducting state.

Authors:  Marcin Kisiel; Enrico Gnecco; Urs Gysin; Laurent Marot; Simon Rast; Ernst Meyer
Journal:  Nat Mater       Date:  2011-01-09       Impact factor: 43.841

Review 2.  Advances in mechanical detection of magnetic resonance.

Authors:  Seppe Kuehn; Steven A Hickman; John A Marohn
Journal:  J Chem Phys       Date:  2008-02-07       Impact factor: 3.488

3.  Giant frictional dissipation peaks and charge-density-wave slips at the NbSe2 surface.

Authors:  Markus Langer; Marcin Kisiel; Rémy Pawlak; Franco Pellegrini; Giuseppe E Santoro; Renato Buzio; Andrea Gerbi; Geetha Balakrishnan; Alexis Baratoff; Erio Tosatti; Ernst Meyer
Journal:  Nat Mater       Date:  2013-12-15       Impact factor: 43.841

4.  Quantifying electric field gradient fluctuations over polymers using ultrasensitive cantilevers.

Authors:  Showkat M Yazdanian; Nikolas Hoepker; Seppe Kuehn; Roger F Loring; John A Marohn
Journal:  Nano Lett       Date:  2009-06       Impact factor: 11.189

  4 in total