Literature DB >> 21724083

Galvanic corrosion between various combinations of orthodontic brackets and archwires.

Arash Bakhtari1, Thomas Gerard Bradley, William K Lobb, David W Berzins.   

Abstract

INTRODUCTION: The purpose of this study was to compare galvanic currents generated by different combinations of commonly used brackets and archwires.
METHODS: As-received stainless steel, nickel-titanium, and beta-titanium wires were coupled to stainless steel and titanium brackets in an artificial saliva medium. The galvanic current and amount of charge transferred for each pair were monitored with a zero resistance ammeter for 10 hours.
RESULTS: Two-way analysis of variance (ANOVA) showed a significant difference in charge and galvanic currents when factored for type of bracket (P <0.001), but no significant difference between them when factored by type of wire (P >0.05). Specifically, a brazed stainless steel bracket was significantly greater in charge transferred and 10-hour galvanic current than metal injection molded stainless steel and titanium brackets (P <0.001), which were not different from each other (P >0.05).
CONCLUSIONS: The method of bracket manufacturing might be of equal or more relevance to galvanic corrosion susceptibility than bracket composition.
Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21724083     DOI: 10.1016/j.ajodo.2010.05.021

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  7 in total

1.  Galvanic coupling of steel and gold alloy lingual brackets with orthodontic wires: Is corrosion a concern?

Authors:  Georgios Polychronis; Youssef S Al Jabbari; Theodore Eliades; Spiros Zinelis
Journal:  Angle Orthod       Date:  2018-03-06       Impact factor: 2.079

2.  Nickel release from stainless steel and nickel titanium archwires - An in vitro study.

Authors:  Huma D Hussain; Sreedevi D Ajith; Prachi Goel
Journal:  J Oral Biol Craniofac Res       Date:  2016-07-02

3.  Longitudinal assessment of periodontal status in patients with nickel allergy treated with conventional and nickel-free braces.

Authors:  Camila Alessandra Pazzini; Leandro Silva Marques; Maria Letícia Ramos-Jorge; Gilberto Oliveira Júnior; Luciano José Pereira; Saul Martins Paiva
Journal:  Angle Orthod       Date:  2011-11-01       Impact factor: 2.079

4.  Galvanic Corrosion of and Ion Release from Various Orthodontic Brackets and Wires in a Fluoride-containing Mouthwash.

Authors:  Soodeh Tahmasbi; Mohammad Ghorbani; Mahdis Masudrad
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2015-09-16

5.  Assessment of the hardness of different orthodontic wires and brackets produced by metal injection molding and conventional methods.

Authors:  Shiva Alavi; Marzie Kachuie
Journal:  Dent Res J (Isfahan)       Date:  2017 Jul-Aug

6.  Corrosive Studies of a Prosthetic Ni-Cr Alloy Coated with Ti(C,N) Type Layers.

Authors:  Katarzyna Banaszek; Marek Maślanka; Michael Semenov; Leszek Klimek
Journal:  Materials (Basel)       Date:  2022-03-27       Impact factor: 3.623

7.  Comparison of Galvanic Currents Generated Between Different Combinations of Orthodontic Brackets and Archwires Using Potentiostat: An In Vitro Study.

Authors:  Rabindra S Nayak; Bareera Shafiuddin; Azam Pasha; K Vinay; Anjali Narayan; Smitha V Shetty
Journal:  J Int Oral Health       Date:  2015-07
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.