In vitro influence of ultrasonic stress, removal force preload and thermocycling on the retrievability of implant-retained crowns.

Christian Mehl1, Sönke Harder, Dorothee Schwarz, Martin Steiner, Oliver Vollrath, Matthias Kern.   

Abstract

OBJECTIVES: The main goals of this in vitro study were to evaluate the influence of thermocycling, ultrasonic stress and the removal force preload on the retrievability of cemented implant crowns using a clinical removal device (Coronaflex) and evaluating the tensile strength using a universal testing machine (UTM).
METHODS: Thirty-six crowns were cast from a Co-Cr alloy for 36 tapered titanium abutments (5° taper, 4.3 mm diameter, 6 mm height, Camlog, Germany). The crowns were cemented with a glass-ionomer (Ketac Cem) or a polycarboxylate (Durelon) cement, followed by 3 days of storage in ionized water without thermocycling or 150 days of storage with 37,500 thermal cycles between 5°C and 55°C. Before removal, the crowns were subjected to ultrasonic stress for 0, 5 or 10 min with a contact pressure of either 50 or 500 g. The Coronaflex was used with a removal force preload of 50 or 400 cN, respectively, applied on the point of loading. Scanning electronic microscopy (SEM) was used to evaluate the impact of the removal on the abutment screws.
RESULTS: Crowns cemented with the glass-ionomer cement were significantly easier to remove with the Coronaflex or the UTM than crowns cemented with the polycarboxylate cement (P≤0.05). Ultrasonic stress showed no significant impact on the retrievability regardless of the contact pressure or duration applied (P>0.05). No significant differences could be found for both cements when removed with the Coronaflex or the UTM (P>0.05) after thermocycling was applied. A removal force preload of 400 cN resulted in significantly reduced removal attempts in comparison with 50 cN for both cements (P≤0.05).
CONCLUSIONS: Ultrasound and thermal cycling did not result in reduced cement strength, but to retrieve the crowns, the full impact of a removal instrument has to be applied. Ketac Cem can be used as a "semipermanent" solution, whereas Durelon might serve for permanent cementation. None of the abutment screws showed signs of wear caused by the removal process.
© 2011 John Wiley & Sons A/S.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21722192     DOI: 10.1111/j.1600-0501.2011.02236.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  3 in total

1.  Retention of different temporary cements tested on zirconia crowns and titanium abutments in vitro.

Authors:  Felix Dähne; Heike Meißner; Klaus Böning; Christin Arnold; Ralf Gutwald; Elisabeth Prause
Journal:  Int J Implant Dent       Date:  2021-07-20

2.  Shear bond strength of luting cements to fixed superstructure metal surfaces under various seating forces.

Authors:  Fusun Ozer; Elif Pak-Tunc; Nesrin Esen Dagli; Deepika Ramachandran; Deniz Sen; Markus Bernhard Blatz
Journal:  J Adv Prosthodont       Date:  2018-10-22       Impact factor: 1.904

3.  Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot.

Authors:  Kyu-Hyung Choi; KeunBaDa Son; Du-Hyeong Lee; Kyu-Bok Lee
Journal:  J Adv Prosthodont       Date:  2018-10-22       Impact factor: 1.904

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.