Literature DB >> 21721445

Evaluation of correlation between vascular pedicle width and intravascular volume status in Thai critically ill patients.

Sanit Wichansawakul1, Warakarn Vilaichone, Surat Tongyoo, Chairat Permpikul, Suwimol Wonglaksanapimol, Kantima Daengnim, Girapong Suwanboonrit.   

Abstract

OBJECTIVE: To evaluate the correlation between vascular pedicle widths (VPW) measured from portable chest roentgenogram (CXR) and intravascular volume status in Thai critically ill patients. MATERIAL AND
METHOD: A prospective cohort study included the critically ill patients in whom pulmonary artery catheter was placed in the Medical Intensive Care Units of Siriraj Hospital, Mahidol University between June 2009 and January 2010. The patient's baseline characteristics, hemodynamic data measured from pulmonary artery catheter (PAC) and CXR parameters were collected.
RESULTS: From thirty-four patients, thirteen (38.2%) had high pulmonary artery occlusive pressure (PAOP > or =18 mmHg). The patients with high PAOP were older (69.8 +/- 8.8 years vs. 59.2 +/- 15.4 years, p = 0.02), taller (163.2 +/- 5.3 cm vs. 157.0 +/- 10.4 cm, p = 0.03) and higher weight (67.4 +/- 12.9 kg vs. 57.1 +/- 7.8 kg, p = 0.007) than the low PAOP group. The correlations between PAOP and VPW (r = 0.68, p < 0.001) as well as between PAOP and cardiothoracic ratio (CTR) (r = 0.23, p = 0.03) were significant. From the receiver operating characteristic (ROC) curve, VPW > 68 mm is the best parameter to predict PAOP > or =18 mmHg (the area under the curve (AUC) = 0.853, p < 0.001, sensitivity = 92.3%, specificity = 85.7%). The CTR > 0.58 can be used to predict elevated PAOP > or =18 mmHg with acceptable sensitivity = 85.74% and specificity = 76.9% (AUC = 0.727, p = 0.03). The peribronchial cuffing (PBC) was detected at a higher percentage among high PAOP group than in the low PAOP group (76.9% vs. 33.3%, p = 0.03).
CONCLUSION: The VPW >68 mm, CTR >0.58 and the present of PBC can be used together to predict elevation of PAOP > or =18 mmHg among the Thai critically ill patients. By using these CXR parameters, the PAC insertion may be avoided especially in patients with contraindication.

Entities:  

Mesh:

Year:  2011        PMID: 21721445

Source DB:  PubMed          Journal:  J Med Assoc Thai        ISSN: 0125-2208


  2 in total

1.  Measurement of the vascular pedicle width predicts fluid repletion: a cross-sectional comparison with inferior vena cava ultrasound and lung comets.

Authors:  Nawal Salahuddin; Iqbal Hussain; Hakam Alsaidi; Quratulain Shaikh; Mini Joseph; Hassan Hawa; Khalid Maghrabi
Journal:  J Intensive Care       Date:  2015-12-22

Review 2.  Fluid responsiveness in acute circulatory failure.

Authors:  Ahmed Hasanin
Journal:  J Intensive Care       Date:  2015-11-19
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.