Locking plates are well suited to complex fracture patterns and weak bone. In the study reported here, we compared the structural stability of 3 different locking compression plate (LCP) constructs using composite analogue humeri. Eighteen analogue composite humeri were used as bone models. A 6.5-mm osteotomy gap was stabalized with a 9-hole 3.5-mm narrow LCP using four 3.5-mm self-tapping screws on each side of the fracture with the middle hole empty. Three construct configurations were studied: B (all screws bicortical), BU (bicortical screw on each side of fracture gap and remaining screws unicortal), and U (all screws unicortal). Each bone model was fixed in a customized jig and subjected to mediolateral and anteroposterior 4-point bending and external rotational torque to assess rigidity, stiffness, and failure. There was significant (P<.05) differences in torsional stiffness but no significant differences in terms of flexural rigidity between each of the constructs. The results also indicated that construct BU provided as much stability as the other constructs. Therefore, consideration should be given to type of fixation construct, especially when torsional stability is required. Replacing a single set of unicortal locking screws with bicortical locking screws closer to the fracture site improved construct stability compared with any unicortal screw construct. A hybrid fixation construct that provides bicortical screws at any location may provide equivalent construct stability in this model. Hybrid fixation constructs may provide adequate fracture stabilization for a fracture pattern that would typically be considered unstable.

Entities:  

Mesh:

Year:  2011        PMID: 21720590

Source DB:  PubMed          Journal:  Am J Orthop (Belle Mead NJ)        ISSN: 1078-4519


  4 in total

1.  The comparison of clinical effect, knee function, prognosis of double plate fixation and locking plate internal fixation for tibial plateau fractures.

Authors:  Qing Zhang; Jianzhong Zhao; Guangcheng Zhang; Jiazhu Tang; Wei Zhu; Mingjun Nie
Journal:  Pak J Med Sci       Date:  2022 Mar-Apr       Impact factor: 2.340

2.  Distal medial tibial locking plate for fixation of extraarticular distal humeral fractures; an alternative choice for fixation.

Authors:  Ali Cagdas Yorukoglu; Ahmet Fahir Demirkan; Nihal Buker
Journal:  Acta Orthop Traumatol Turc       Date:  2018-05-04       Impact factor: 1.511

3.  Is Bridge Plating of Comminuted Humeral Shaft Fractures Advantageous When Using Compression Plates with Three versus Two Screws per Fragment? A Biomechanical Cadaveric Study.

Authors:  Guilherme Seva Gomes; Ivan Zderic; Marc-Daniel Ahrend; Kodi E Kojima; Peter Varga; William Dias Belangero; Geoff Richards; Simon M Lambert; Boyko Gueorguiev
Journal:  Biomed Res Int       Date:  2021-03-06       Impact factor: 3.411

4.  Biomechanical Study of the Fixation Strength of Anteromedial Plating for Humeral Shaft Fractures.

Authors:  Yin-Feng Zheng; Jun-Lin Zhou; Xiao-Hong Wang; Lei Shan; Yang Liu
Journal:  Chin Med J (Engl)       Date:  2016-08-05       Impact factor: 2.628

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.