Literature DB >> 21720573

Knot security, loop security, and elongation of braided polyblend sutures used for arthroscopic knots.

Ryan W Livermore1, Alexander C M Chong, Daniel J Prohaska, Francis W Cooke, Teresa L Jones.   

Abstract

In the study described here, we evaluated load to failure and cyclic loading elongation of different braided polyblend sutures under different sliding knot configurations. Four braided polyblend sutures (FiberWire, Herculine, Orthocord, Ultrabraid) were tied with 5 sliding arthroscopic knots (Static surgeon, Weston, Roeder, Nicky, Tennessee slider) with a series of 3 reversing half-hitches on alternating posts (RHAPs). Each knot was tied around a 30-mm circumference post to ensure a consistent loop circumference. Loop security was measured as load to failure (load at 3-mm cross-head displacement or suture breakage) and loop elongation at a frequency of 1 Hz from 6 N to 30 N for 1000 cycles. Twenty knots were tied for each possible combination of knots and sutures, 10 for load to failure and 10 for cyclic loading test. For any given knot type, tying with Ultrabraid suture material resulted in maximum performance in the maximum load-to-failure test. Conversely, tying with Orthocord resulted in a significantly lower maximum load to failure, with the exception of the Surgeon knot. The Weston knot with 3 RHAPs using Ultrabraid provided the highest load to failure(mean, 346 N; SD, 24 N). All knots elongated less than 0.45 mm at the 1000th cycle and experienced higher suture slippage at initial cyclic loading (50th cycles). At higher cycles, FiberWire and Orthocord demonstrated less than half of the suture slippage of Herculine and Ultrabraid (5x10(-5) vs 11x10(-5) mm/cycle). Different braided polyblend sutures provide different knot and loop security for a given type of sliding knot. All knots in this study appear to be durable with respect to resistance to loosening under cyclic loading conditions. The Weston knot with 3 RHAPs using Ultrabraid provided the best loop and knot security. Our study results help further our understanding of the biomechanics of knot and loop security differences for different braided polyblend sutures.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21720573

Source DB:  PubMed          Journal:  Am J Orthop (Belle Mead NJ)        ISSN: 1078-4519


  10 in total

1.  A Biomechanical Comparison of Varying Base Knot Configurations with Different Overhand/Underhand Combinations of Reversing Half-Hitches on Alternating Posts After Basic Instructional Training.

Authors:  Heather A Evin; Tyler T Bilden; Benjamin C Noonan; Alexander Cm Chong
Journal:  Iowa Orthop J       Date:  2019

2.  The Effect of Different Combinations of Three Stacked Half-Hitches and Suture Materials on an Arthroscopic Knot in a Dry or Wet Environment.

Authors:  Alexander Cm Chong; Jordan L Ochs; Rosalee E Zackula; Lisa N MacFadden; Daniel J Prohaska
Journal:  Iowa Orthop J       Date:  2018

3.  Reverse Flipping Technique: An Alternate Approach to Tie Reversing Half-Hitches on Alternating Posts.

Authors:  Alexander C M Chong; Daniel J Prohaska; Ryan C Pate
Journal:  Arthrosc Tech       Date:  2016-04-25

4.  Strength of Resistance to "Flip" the Tightened Half-Hitches of an Arthroscopic Knot.

Authors:  Alexander Cm Chong; Pie Pichetsurnthorn; Daniel J Prohaska
Journal:  Iowa Orthop J       Date:  2017

5.  Suture Breakage Warning System for Robotic Surgery.

Authors:  Ahmad Abiri; Syed J Askari; Anna Tao; Yen-Yi Juo; Yuan Dai; Jake Pensa; Robert Candler; Erik P Dutson; Warren S Grundfest
Journal:  IEEE Trans Biomed Eng       Date:  2018-09-10       Impact factor: 4.538

6.  Loop and knot security of a novel arthroscopic sliding-locking knot using high-strength sutures.

Authors:  Cpt Sally Corey; Karl Wenger; Cpt Peter Johnson; Maj Stephen Parada
Journal:  J Orthop       Date:  2018-08-24

7.  Validation of Different Combination of Three Reversing Half-Hitches Alternating Posts (RHAPs) Effects on Arthroscopic Knot Integrity.

Authors:  Alexander Cm Chong; Daniel J Prohaska; Brian P Bye
Journal:  Kans J Med       Date:  2017-05-15

8.  Enhanced Tendon-to-Bone Healing of Chronic Rotator Cuff Tears by Bone Marrow Aspirate Concentrate in a Rabbit Model.

Authors:  Xiao Ning Liu; Cheol-Jung Yang; Ji Eui Kim; Zhen Wu Du; Ming Ren; Wei Zhang; Hong Yu Zhao; Kyung Ok Kim; Kyu-Cheol Noh
Journal:  Clin Orthop Surg       Date:  2018-02-27

9.  Comparing the Influence of Different Overhand/Underhand Stacking Combinations of Reversing Half-Hitches on Alternating Posts on Arthroscopic Knot Security.

Authors:  Tyler T Bilden; Heather A Evin; Benjamin C Noonan; Alexander C M Chong
Journal:  Kans J Med       Date:  2019-11-25

10.  Knots Tied With High-Tensile Strength Tape Biomechanically Outperform Knots Tied With Round Suture.

Authors:  Chih-Kai Hong; Hao-Chun Chuang; Kai-Lan Hsu; Fa-Chuan Kuan; Yueh Chen; Ming-Long Yeh; Wei-Ren Su
Journal:  Orthop J Sports Med       Date:  2021-10-13
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.