Sequential eluent injection technique as a new approach for the on-line enrichment and speciation of Cr(III) and Cr(VI) species on a single column with FAAS detection.

M Arab Chamjangali1, N Goudarzi, M Mirheidari, B Bahramian.   

Abstract

This paper introduces a sequential eluent injection (SEI) technique combined with an on-line preconcentration/separation system for a fast and sensitive FAAS determination of trace amounts of Cr(III) and Cr(VI) species. The method is based on the simultaneous retention of Cr(III) and Cr(VI) on a single mini-column packed with a chloromethylated polystyrene functionalized with N,N-bis(naphthylideneimino)diethylenetriamine (PS-NAPdien) at pH 6.7. The retained chromium species was eluted by sequential injection of HCl for desorption of Cr(III), and NH(3) and NH(4)NO(3) buffer solutions for desorption of Cr(VI). All the chemical and flow injection variables were optimized for the quantitative preconcentration and speciation of Cr(III) and Cr(VI). Under the optimum conditions, the calibration graph obtained is linear over the concentration range of 2.0-60.0μg L(-1) for Cr(III), and 8.0-180.0μg L(-1) for Cr(VI). The preconcentration factors for Cr(III) and Cr(VI) were 70 and 30, respectively. The 3σ detection limits were 0.6μg L(-1) and 2.5μg L(-1) for Cr(III) and Cr(VI), respectively. The relative standard deviations were 2.55% and 0.8%, respectively, for 6 replicate determinations of Cr(III) and Cr(VI) at the 40.0μg L(-1) level. The proposed method was applied for determination of Cr(III) and Cr(VI) in different water samples with satisfactory results.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21719192     DOI: 10.1016/j.jhazmat.2011.05.095

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  2 in total

1.  A Novel Glass Fiber Coated with Sol-Gel Poly-Diphenylsiloxane Sorbent for the On-Line Determination of Toxic Metals Using Flow Injection Column Preconcentration Platform Coupled with Flame Atomic Absorption Spectrometry.

Authors:  Eleni Lazaridou; Abuzar Kabir; Kenneth G Furton; Aristidis Anthemidis
Journal:  Molecules       Date:  2020-12-22       Impact factor: 4.411

2.  Green fluorescent nanomaterials for rapid detection of chromium and iron ions: wool keratin-based carbon quantum dots.

Authors:  Yuanyuan Song; Na Qi; Kang Li; Di Cheng; Dong Wang; Ying Li
Journal:  RSC Adv       Date:  2022-03-11       Impact factor: 3.361