Intraoperative near-infrared indocyanine green-videoangiography (ICG-VA) and graphic analysis of fluorescence intensity in cerebral aneurysm surgery.

Jumpei Oda1, Yoko Kato, S F Chen, Paresh Sodhiya, T Watabe, S Imizu, D Oguri, H Sano, Y Hirose.   

Abstract

We present our preliminary experience with intraoperative near-infrared indocyanine green-videoangiography (ICG-VA) and analysis of blood flow dynamics using fluorescence intensity assessment in cerebral aneurysm clipping surgery. Thirty-nine patients with 43 intracranial aneurysms underwent microsurgical clipping. Intraoperative ICG-VA was performed before and after clip application. An infrared fluorescence module integrated into a surgical microscope was used to visualize fluorescence in the surgical field and we recorded the emitted fluorescent light. An integrated analytical visualization tool simultaneously analyzed the video sequence and converted it into an intensity diagram, which allowed an objective evaluation of the results rather than the subjective assessment of fluorescence using ICG-VA. Overall, ICG-VA was performed 137 times. Incomplete clipping was detected in four patients, which allowed suitable adjustment to completely obliterate the aneurysm. In 12 patients, perforators arising close to, or from, the aneurysmal neck were identified in the surgical field. In three patients, the ICG-VA intensity diagram provided valuable information leading to modification of the primary surgical maneuver. ICG-VA provides high resolution images allowing real-time assessment of the blood flow in the parent artery and arterial branches, including the perforators. The intensity diagram is useful for providing a more objective record of the hemodynamics than the traditional ICG-VA, which relies more on subjective assessment and may allow interobserver variability. We conclude that ICG-VA, combined with the intensity diagram, can reduce the morbidity and complications associated with aneurysm clipping and improve patient outcomes.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21715173     DOI: 10.1016/j.jocn.2010.12.045

Source DB:  PubMed          Journal:  J Clin Neurosci        ISSN: 0967-5868            Impact factor:   1.961


  11 in total

1.  Evaluation of changes of intracranial blood flow after carotid artery stenting using digital subtraction angiography flow assessment.

Authors:  Hajime Wada; Masato Saito; Kyousuke Kamada
Journal:  World J Radiol       Date:  2015-02-28

2.  Comparative analysis of fluorescent angiography, computed tomographic angiography and magnetic resonance angiography for planning autologous breast reconstruction.

Authors:  Michael P Chae; David J Hunter-Smith; Warren Matthew Rozen
Journal:  Gland Surg       Date:  2015-04

Review 3.  Indocyanine green videoangiography methodological variations: review.

Authors:  Juan A Simal-Julián; Pablo Miranda-Lloret; Rocio Evangelista-Zamora; Pablo Sanromán-Álvarez; Laila Pérez de San Román; Pedro Pérez-Borredá; Andrés Beltrán-Giner; Carlos Botella-Asunción
Journal:  Neurosurg Rev       Date:  2014-08-30       Impact factor: 3.042

4.  Intraoperative indocyanine green video angiography (ICG-VA) with FLOW 800 software in complex intracranial aneurysm surgery.

Authors:  Tao Xue; Ruming Deng; Bixi Gao; Zilan Wang; Chao Ma; Wanchun You; Yun Zhu; Zhouqing Chen; Zhong Wang
Journal:  Chin Neurosurg J       Date:  2021-06-01

5.  Impact of Virtual Reality in Arterial Anatomy Detection and Surgical Planning in Patients with Unruptured Anterior Communicating Artery Aneurysms.

Authors:  Samer Zawy Alsofy; Ioanna Sakellaropoulou; Makoto Nakamura; Christian Ewelt; Asem Salma; Marc Lewitz; Heinz Welzel Saravia; Hraq Mourad Sarkis; Thomas Fortmann; Ralf Stroop
Journal:  Brain Sci       Date:  2020-12-10

Review 6.  Fluorescence imaging in surgery.

Authors:  Ryan K Orosco; Roger Y Tsien; Quyen T Nguyen
Journal:  IEEE Rev Biomed Eng       Date:  2013-01-15

Review 7.  Molecular imaging of experimental abdominal aortic aneurysms.

Authors:  Aneesh K Ramaswamy; Mark Hamilton; Rucha V Joshi; Benjamin P Kline; Rui Li; Pu Wang; Craig J Goergen
Journal:  ScientificWorldJournal       Date:  2013-04-23

8.  A review of indocyanine green fluorescent imaging in surgery.

Authors:  Jarmo T Alander; Ilkka Kaartinen; Aki Laakso; Tommi Pätilä; Thomas Spillmann; Valery V Tuchin; Maarit Venermo; Petri Välisuo
Journal:  Int J Biomed Imaging       Date:  2012-04-22

9.  Role of endoscopy in multi-modality monitoring during aneurysm surgery: A single center experience with 175 consecutive unruptured aneurysms.

Authors:  Yasuhiro Yamada; Yoko Kato; Kohei Ishihara; Keisuke Ito; Takafumi Kaito; Mohsen Nouri; Motoki Oheda; Joji Inamasu; Yuichi Hirose
Journal:  Asian J Neurosurg       Date:  2015 Jan-Mar

10.  Quantitative analysis of intraoperative indocyanine green video angiography in aneurysm surgery.

Authors:  Young-Je Son; Jeong Eun Kim; Sung Bae Park; Sang Hyung Lee; Young Seob Chung; Hee-Jin Yang
Journal:  J Cerebrovasc Endovasc Neurosurg       Date:  2013-06-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.