Literature DB >> 21713593

Comparison of two electromyographical endotracheal tube systems for intraoperative recurrent laryngeal nerve monitoring: reliability and side effects.

Torsten Birkholz1, Christina Saalfrank-Schardt, Andrea Irouschek, Peter Klein, Sven Albrecht, Joachim Schmidt.   

Abstract

BACKGROUND: Recurrent laryngeal nerve (RLN) monitoring systems should be reliable and safe. Monitoring via electromyographical systems on an endotracheal tube (ETT) is widely spread. The MagStim™ system consists of an adhesive electrode to be fixed on an endotracheal tube. The Xomed™ endotracheal tube provides integrated electrodes. Reliability and side effects had never been compared. As both systems have very different morphological properties, we hypothesized that there might be differences in reliability and the incidence of side effects.
METHODS: In a retrospective quality management analysis of 118 patients (MagStim™ electrode, 57 patients; Xomed™ ETT, 61 patients), we compared laryngeal side effects according to the Chilla score and detection rate of the RLN.
RESULTS: Both systems had comparable detection rates of the RLN above 95%. Both electrode systems seemed to have similar reliability. Difficulties to detect the nerve were observed in seven patients (four with MagStim, three with Xomed). In the group with the Xomed™ ETT, significantly less mild laryngeal side effects were observed.
CONCLUSION: Both MagStim™ and Xomed™ ETT were reliable in detecting the RLN. The Xomed™ ETT, however, might cause milder laryngeal side effects compared with the MagStim™ electrode.

Entities:  

Mesh:

Year:  2011        PMID: 21713593     DOI: 10.1007/s00423-011-0819-2

Source DB:  PubMed          Journal:  Langenbecks Arch Surg        ISSN: 1435-2443            Impact factor:   3.445


  16 in total

1.  [Intraoperative electromyographic recurrent laryngeal nerve identification as a routine measure].

Authors:  T M Hemmerling; C Schurr; S Dern; J Schmidt; G G Braun; P Klein
Journal:  Chirurg       Date:  2000-05       Impact factor: 0.955

2.  Intraoperative monitoring of the recurrent laryngeal nerve in 151 consecutive patients undergoing thyroid surgery.

Authors:  T M Hemmerling; J Schmidt; C Bosert; K E Jacobi; P Klein
Journal:  Anesth Analg       Date:  2001-08       Impact factor: 5.108

3.  Laryngeal morbidity and quality of tracheal intubation: a randomized controlled trial.

Authors:  Thomas Mencke; Mathias Echternach; Stefan Kleinschmidt; Philip Lux; Volker Barth; Peter K Plinkert; Thomas Fuchs-Buder
Journal:  Anesthesiology       Date:  2003-05       Impact factor: 7.892

4.  Monitoring performance in thyroidectomy: cumulative sum analysis of outcomes.

Authors:  Timothy M Connolly; David A K Watters
Journal:  Thyroid       Date:  2010-04       Impact factor: 6.568

5.  Nerve monitoring and stimulation during endoscopic neck surgery in the pig.

Authors:  Lisa Danielle Grunebaum; David Rosen; Howard D Krein; William M Keane; Mark Curtis; Debra A Tereschuk; Edmund A Pribitkin
Journal:  Laryngoscope       Date:  2005-04       Impact factor: 3.325

6.  Impact of modern technologies on quality of thyroid surgery.

Authors:  Henning Dralle
Journal:  Langenbecks Arch Surg       Date:  2006-02       Impact factor: 3.445

7.  [The short-time-intubation as a cause of morphological and functional disorders of the larynx (author's transl)].

Authors:  R Chilla; P Gabriel; H Ilse
Journal:  Laryngol Rhinol Otol (Stuttg)       Date:  1976-02

8.  [Cuff damage of the tracheal mucosa in intubation. Experimental examinations of the trachea of the human corpse (author's transl)].

Authors:  H Frühwald; R Schmiedl
Journal:  Laryngol Rhinol Otol (Stuttg)       Date:  1980-11

9.  Standardization of intraoperative neuromonitoring of recurrent laryngeal nerve in thyroid operation.

Authors:  Feng-Yu Chiang; Ka-Wo Lee; Hui-Chun Chen; Hsiu-Ya Chen; I-Cheng Lu; Wen-Rei Kuo; Ming-Chia Hsieh; Che-Wei Wu
Journal:  World J Surg       Date:  2010-02       Impact factor: 3.352

10.  [Dysphonia following strumectomy. Laryngeal and vocal cord changes as sequelae of thyroid surgery].

Authors:  P Gabriel; R Chilla
Journal:  Chirurg       Date:  1978-09       Impact factor: 0.955

View more
  3 in total

1.  Endemic goiter--individual risk factors necessitate individual treatment.

Authors:  M Schneider; T Welsch; M Kremer; M W Büchler
Journal:  Langenbecks Arch Surg       Date:  2011-12       Impact factor: 3.445

2.  [Intraoperative neuromonitoring in thyroid surgery. Recommendations of the Surgical Working Group for Endocrinology].

Authors:  H Dralle; K Lorenz; P Schabram; T J Musholt; C Dotzenrath; P E Goretzki; J Kußmann; B Niederle; C Nies; J Schabram; C Scheuba; D Simon; T Steinmüller; A Trupka
Journal:  Chirurg       Date:  2013-12       Impact factor: 0.955

3.  Intraoperative neural monitoring in head and neck surgeries: Feasibility and concerns.

Authors:  Manpreet Kaur
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2019 Jan-Mar
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.