Stability and rheology of dilute TiO2-water nanofluids.

Vera Penkavova1, Jaroslav Tihon, Ondrej Wein.   

Abstract

The apparent wall slip (AWS) effect, accompanying the flow of colloidal dispersions in confined geometries, can be an important factor for the applications of nanofluids in heat transfer and microfluidics. In this study, a series of dilute TiO2 aqueous dispersions were prepared and tested for the possible presence of the AWS effect by means of a novel viscometric technique. The nanofluids, prepared from TiO2 rutile or anatase nanopowders by ultrasonic dispersing in water, were stabilized by adjusting the pH to the maximum zeta potential. The resulting stable nanofluid samples were dilute, below 0.7 vol.%. All the samples manifest Newtonian behavior with the fluidities almost unaffected by the presence of the dispersed phase. No case of important slip contribution was detected: the Navier slip coefficient of approximately 2 mm Pa-1 s-1 would affect the apparent fluidity data in a 100-μm gap by less than 1%.

Entities:  

Year:  2011        PMID: 21711783      PMCID: PMC3211337          DOI: 10.1186/1556-276X-6-273

Source DB:  PubMed          Journal:  Nanoscale Res Lett        ISSN: 1556-276X            Impact factor:   4.703


Background

Bulk rheological properties of nanofluids (shear viscosity [1,2], yield stress [3-7], and complex modulus [8]) can be important factors for some applications (e.g., convective heat transfer [9,10], and filtration [5]) and can also provide some correlations with other properties, such as volumetric particle concentration [1,2], thermal conductivity [11,12], or ξ-potential [3-6]. On the other hand, there are processes with a dominant microscopic length scale, such as small Nernst diffusion thickness in heat/mass transfer [13], small hydraulic radius in microfluidics [14-17], small pore diameter in filtration [5], etc., where the bulk rheology characteristics should be completed using another kind of information. In some cases, two-scale description (particle size or inter-particle distance vs. hydraulic radius) is useful [15]. In other cases, an additional macroscopic interfacial property, like apparent wall slip (AWS) velocity [18,19], could provide the missing information. In this study, we examine experimentally the AWS effect in dilute TiO2-water nanofluids, using a novel AWS viscometric technique [19].

Experimental procedure

Preparation and stability of the samples

Sample nanofluids were prepared by dispersing a nanopowder in an aqueous electrolyte solution (the base solution). The TiO2 nanopowders (A1, A2, A3, R1, and R2) used in this study are specified in Table 1. The base solutions with adjusted pH values were prepared by adding HCl or NaOH to demineralized water with a possible content of dissolved gases.
Table 1

Nanopowders used for the preparation of nanofluids

PowderMineralSourceDensity (g cm-3)Max. size (nm)
A1TiO2 anataseAldrich3.9025
A2TiO2 anataseICPFa3.9040
A3TiO2 anataseICPFa3.9020
R1TiO2 rutileAldrich4.17100
R2TiO2 rutilePrechezab4.17100

aICPF - nanopowder for photocatalytic application supplied by Department of Catalysis of ICPF ASCR, Prague

bPrecheza - commercial pigment, produced by Prerov Chemical Works, Czech Republic

Nanopowders used for the preparation of nanofluids aICPF - nanopowder for photocatalytic application supplied by Department of Catalysis of ICPF ASCR, Prague bPrecheza - commercial pigment, produced by Prerov Chemical Works, Czech Republic In preliminary experiments, 0.02 g of a nanopowder was added into 25 mL of each base solution. The flask with a suspension was treated for 30 min in a 40-kHz ultrasonic bath with a nominal acoustic power of 30 kW m-3. The samples were then tested using DLS technique (Zetasizer Nano ZS - Malvern Instruments) to determine the zeta potential, ξ. Actual values of pH, see Figure 1, slightly differ from idealized log-linear estimates (dotted line in Figure 1) even for a series of the base solutions. This difference is caused by dissociation of water and hydrated TiO2, as well as by the presence of dissolved CO2 (around cNaOH = 10-5 mol/L). The resulting ξ-potentials dependent on the actual measured pH values are plotted in Figure 2.
Figure 1

Titration curves of the tested samples. Dotted line shows an idealized titration curve. Deviations for the individual samples are due to dissociation of hydrated TiO2 and dissolved CO2.

Figure 2

Acidobasic adjusting of . Individual nanopowders are specified in Table 1.

Titration curves of the tested samples. Dotted line shows an idealized titration curve. Deviations for the individual samples are due to dissociation of hydrated TiO2 and dissolved CO2. Acidobasic adjusting of . Individual nanopowders are specified in Table 1. Assuming that the maximum stability of a TiO2-water dispersion, i.e., the highest resistance against sedimentation, can be achieved at the extreme values of ξ-potential [1], further ten samples (A1±, A2±, A3±, R1±, and R2±), were prepared to examine their particle size distribution using again the DLS technique; see also Table 2. The preparation of these samples differs from the preliminary procedure only in the utilization of a larger primary amount of nanopowder (2.5 g in 100 g of dispersion) and a longer ultrasonication time (24 h). An external cooling system was employed to keep the sample at a constant temperature of 23°C during ultrasonic treatment. After keeping the sample aside for next 8 h, the sediment (ranging from 5 to 90% of the original content of nanopowder) was withdrawn and weighed to determine the final real particle concentration, shown in Table 2.
Table 2

Parameters of the stable nanofluids

SamplePowderBase solutionpHξ (mV)Conc. TiO2 (wt.%)Conc. TiO2 (vol.%)
A1+A110-2 M HCl2.469.41.20.31
A1-aA110-3 M NaOH12.4-42.70.8b0.2a
A2+A210-2 M HCl2.481.22.40.65
A2-aA210-3 M NaOH12.4-44.31.2*0.3*
A3+A310-2 M HCl2.4871.40.36
A3-aA310-3 M NaOH12.3-44.50.8*0.2*
R1+aR110-2 M HCl2.4-0.2*0.05*
R1-R110-2 M NaOH12.4-65.20.20.05
R2+aR210-2 M HCl2.434.90.2a0.05a
R2-R210-2 M NaOH12.4-61.60.30.07

Volumetric concentrations were calculated using the densities from Table 1.

aUnstable samples with rough estimates of particle concentration.

Parameters of the stable nanofluids Volumetric concentrations were calculated using the densities from Table 1. aUnstable samples with rough estimates of particle concentration. The resulting particle size distributions, Figure 3, show remarkable differences in the behaviors of anatase- and rutile-based dispersions. While the anatase dispersions display the maximum content of the finest particles in acid media (A1+, A2+, and A3+), the rutile dispersions in acid media (R1+ and R2+) are much more coarse. In alkaline media, on the contrary, the anatase dispersions (A1-, A2-, and A3-) display a remarkable shift toward coarse clusters, whereas the rutile dispersions (R1- and R2-) become finer. As a matter of fact, the coarser dispersions (A1-, A2-, A3-, R1+, and R2+) settle rather fast, while the finer dispersions (A1+, A2+, A3+, R1-, and R2-) are stable for a few days. Only the stable dispersions were further subjected to rheological examinations using the AWS rotational viscometry.
Figure 3

Particle size distributions via DLS method. Color and style of the curves identifies the samples, specified in Table 2. Note a large volumetric content of coarse particles in the anatase sample A1+ and in all the rutile samples. This is apparent in the volume-weighed distributions, while almost hidden in the number-weighed distributions.

Particle size distributions via DLS method. Color and style of the curves identifies the samples, specified in Table 2. Note a large volumetric content of coarse particles in the anatase sample A1+ and in all the rutile samples. This is apparent in the volume-weighed distributions, while almost hidden in the number-weighed distributions.

AWS rotational viscometry

The concept of AWS effect from the viscometric viewpoint [17-19] is illustrated in Figure 4 for the simple shear flow between two mutually sliding parallel plates. A possible near-wall flow anomaly, resulting in a non-linear velocity profile under constant shear stress σ, is represented by the apparent slip velocity u. The only experimentally available kinematic quantity, the sliding velocity U, determines the apparent shear rate γapp ≡ U/h (or γapp = ΩR/h for the Couette flow in a narrow gap h between two coaxial cylinders), which is expressed as a sum of the bulk flow and wall slip contributions, as follows:
Figure 4

Scheme of a shear flow with the AWS effect. Dotted line - actual non-linear velocity profile observed at the constant shear stress σ due to the effect of a depletion layer of dispersion at the wall; Broken solid line - approximation of the actual velocity profile, introduced by the concept of AWS [18]. U = γh + 2u - macroscopic sliding velocity, m s-1; h - gap thickness, m; u - AWS velocity, m s-1; γ - bulk shear rate, s-1.

Scheme of a shear flow with the AWS effect. Dotted line - actual non-linear velocity profile observed at the constant shear stress σ due to the effect of a depletion layer of dispersion at the wall; Broken solid line - approximation of the actual velocity profile, introduced by the concept of AWS [18]. U = γh + 2u - macroscopic sliding velocity, m s-1; h - gap thickness, m; u - AWS velocity, m s-1; γ - bulk shear rate, s-1. Two material functions, the bulk fluidity φ[σ] ≡ γ/σ and the Navier slip coefficient χ[σ] ≡ u/σ, are constant in many cases [17-19]. The flow and slip effects can be distinguished through a series of viscometric experiments, in which the gap thickness h is systematically varied whereas the shear stress σ is kept constant. This is the essence of AWS viscometry.

Rotational viscometer with a KK sensor

The experimental realization of AWS viscometry needs a series of sensors of different and well-calibrated hydraulic radii (tube radius in the capillary viscometry, gap thickness between cup and bob in the rotational viscometry, etc.). The novel KK-type sensor for the rotational AWS viscometry [19], shown in Figure 5 complies with this need by means of an axial shift facility for adjusting Δz and, subsequently, the gap thickness h is given by
Figure 5

KK sensor for AWS viscometry operating under HAAKE RS 600 rotational viscometer. Common geometry parameters for all the KK sensors: H = 60 mm, R = 17.5 mm, cot(θ) = 10. The actual gap thickness h is adjustable through axial shift Δz, see Equation 2. When applying Equation 1 for description of the AWS effect, take ΩR = U.

KK sensor for AWS viscometry operating under HAAKE RS 600 rotational viscometer. Common geometry parameters for all the KK sensors: H = 60 mm, R = 17.5 mm, cot(θ) = 10. The actual gap thickness h is adjustable through axial shift Δz, see Equation 2. When applying Equation 1 for description of the AWS effect, take ΩR = U. where h0 corresponds to h at the starting position Δz = 0. Both the working surfaces of the sensor are the coaxial cones of the same cone angle θ, as in a Morse clutch. The gap thickness can be adjusted over a broad range of 100-2500 μm with substantially (ten times) higher accuracy than for the plate-plate (PP) sensor. At the same time, the KK sensor displays much lesser edge effects and better reproducibility. In many applications, it is important to note that the measurements with a varied gap thickness can be made without refilling samples. The fully automated rotational rheometer HAAKE RS 600 has been used both for driving the KK sensors and for data acquisition. When operating the KK sensor under HAAKE software RheoWin, it is appropriate to identify it with a PP-type sensor. Primary data in the text files, generated by the HAAKE RheoWin software, were further treated using a home-made software AWSWork, described in [19].

Correction on centrifugal effects in AWS rotational viscometry

The original theory [19] of the KK sensors ignores possible inertia effects at the edges of rotating spindle. An additional correction E of the shear stress on inertia was until now considered only for the standard cylinder-cylinder Z40 DIN sensor [20]. This result can be rearranged to a local edge correction for a single semi-infinite cylinder by radius R rotating with a speed Ω in an infinite coaxial cylindrical vessel by radius R + h = R(1 + κ), filled with a Newtonian liquid of kinematic viscosity υ = 1/(φρ): where κ ≡ h/R, Re ≡ ΩR2/υ, a = 7.0 × 10-4, and b = 2.7 × 10-4. For a KK-type conical spindle, the local edge effects are related to different radii at the both fronts, R and λR, respectively, with a common h and λ = 1 - tan(θ) H/R, Figure 5. The final correction on centrifugal effects can be approximated for Newtonian liquids by the formula:

Results and discussion

Stability and texture of dilute nanofluids

All the TiO2 dispersions, prepared in the described way, were partially settling down. The concentrations of the final stable dispersions depend on the base solution used, individual nanopowder, and dispersion procedure. The series of images in Figure 6 illustrates the influence of the dispersion procedure and base solution on the texture of several dispersions of the nanopowder A3. The photographs were obtained using the SEM imaging technique (Cameca SX100), applied to the samples of the dried drops. In conclusion, the particles of the nanopowder A3 were better dispersed in the acidic solution than in the neutral or alkaline one (compare Figure 6a, b, c). The clusters remaining in the acid dispersion were broken up during the ultrasonic treatment (compare Figure 6c, d).
Figure 6

Examples of SEM images of dried samples. The representative photographs were selected for each tested sample. In contrast to the samples (a, b), the samples (c, d) contain a major part of the nanopowder in the form of fine particles. In addition, the long-time ultrasonification, see sample (d), breaks-up the remaining clusters apparent in sample (c). The specification of A3 nanopowder is given in Table 1.

Examples of SEM images of dried samples. The representative photographs were selected for each tested sample. In contrast to the samples (a, b), the samples (c, d) contain a major part of the nanopowder in the form of fine particles. In addition, the long-time ultrasonification, see sample (d), breaks-up the remaining clusters apparent in sample (c). The specification of A3 nanopowder is given in Table 1. The influence of pH on the quality of dispersions was observed for all the tested dispersions via DLS technique. It can be seen from the number and volume-weighted particle size distributions (Figure 3) that anatase nanopowders disperse better in the acid solutions while rutile ones in the alkali solutions. The finer the dispersion the higher the concentration in the final stable samples. Rheological measurements were conducted using the AWS rotational viscometry on the HAAKE RS 600 commercial instrument with a series of home-made KK sensors. Basic characterization of the examined samples is given in Table 2. As the AWS effect can depend on the material type and roughness of confining surfaces of the sensors, four different KK sensors were used, see Table 3. For the each combination sample - KK sensor, a series of individual viscometric measurements was made, covering the range of shear stress σ ∈ 0.05-5 Pa and the range of gap thickness h ∈ 150-500 μm. In the final data treatment, including the inertia correction according to Equations 3 and 4, the primary data with σ > 1 Pa or h > 300 μm were disregarded (errors due to inertia effects over 5%). Uncorrected AWS data on φ and χ, not shown here, display remarkable dependence on σ, evoking a shear-thickening behavior. However, the correction of primary data on inertia effects shows that this dependence is only an experimental artifact.
Table 3

The KK sensors for AWS rotational viscometry

SensorMaterialh0 (μm)
KK01Stainless steel173.5 ± 2
KK02Titanium134.5 ± 2
KK03Eloxed dural131.5 ± 2
KK04Sand-blasted stainless steel150.6 ± 2

All sensors share the nominal dimensions R = 17.5 mm; H = 60 mm; cot θ = 10.

The minimum gap thicknesses h0 were determined by calibrations with water.

The KK sensors for AWS rotational viscometry All sensors share the nominal dimensions R = 17.5 mm; H = 60 mm; cot θ = 10. The minimum gap thicknesses h0 were determined by calibrations with water. The AWS data were further treated to separate the flow and slip contributions and to identify the corresponding material functions φ[σ] and χ[σ]. The resulting fluidities, given in Table 4, do not deviate from that of pure water by more than 3%. Statistical estimates of the slip extrapolation length β [19],
Table 4

Results of rheological measurements at 23°C

SampleFluidity φ (Pa-1 s-1)

KK01KK02KK03KK04All sensors

AvgDevAvgDevAvgDevAvgDevAvgDev
A1+103216102647104910103111103610
A2+10456104161045610411010432
A3+10011010288102218100940101512
R1-101819103122106013106914104524
R2-104210104531107312103045104818
Water103317

Avg & Dev, average and standard deviation for a given data series.

Results of rheological measurements at 23°C Avg & Dev, average and standard deviation for a given data series. given in Table 5, indicate the mean values about zero with uncertainty about ±2 μm. This is in a good agreement with the estimate of instrumental uncertainty Δh of the adjustable gap thickness h, given in Table 3. Possible slip effects in all the studied samples are therefore quite negligible in comparison with the instrumental uncertainty.
Table 5

Results of rheological measurements at 23°C

SampleSlip extrapolation length β = χ/φ (μm)

KK01KK02KK03KK04

AvgDevAvgDevAvgDevAvgDev
A1+22026202
A2+22022222
A3+95123355
R1-33535555
R2-64927344
Water02

Avg & Dev, average and standard deviation for a given data series.

Results of rheological measurements at 23°C Avg & Dev, average and standard deviation for a given data series. The absence of slip effect is illustrated also in Figure 7, where the AWS data are fitted on two different constitutive models according to Equation 1, for details on the parametric filtration see [19]. Figure 7a shows the results obtained for the model with no-slip assumption, χ = 0, while the Figure 7b shows those for the model with adjustable but constant χ. Comparing of the both approaches shows that they provide nearly same estimates of the fluidity.
Figure 7

Example of treating primary AWS data. The example corresponds to sample A1 in KK01 sensor: (a) using constitutive model with no AWS (zero slip coefficient); (b) using constitutive model with adjustable constant slip coefficient.

Example of treating primary AWS data. The example corresponds to sample A1 in KK01 sensor: (a) using constitutive model with no AWS (zero slip coefficient); (b) using constitutive model with adjustable constant slip coefficient.

Conclusions

AWS rotational viscometry with KK-type sensors represents a novel technique suitable for testing microdisperse fluids in the presence of slip effects. Several dilute TiO2-water stable nanofluids with an optimized pH (via ξ-potential) are used to demonstrate the capability of this instrumentation to detect possible slip effects even in low-viscosity liquid samples. The tested stable colloidal samples differ in the nominal volumetric concentrations of nanoparticles, ranging from 0.07 to 0.7 vol.%. The sensitivity of the AWS viscometric instrument on slip effects depends on the minimum available gap thickness and the accuracy of its adjustment. Within the given instrumentational limits, no slip effect was detected for the nanofluid samples examined for this investigation.

Abbreviations

AWS: apparent wall slip.

Competing interests

The authors declare that they have no competing interests.

Authors' contributions

VP carried out experiments, and evaluations, including development of special software. JT participated as a consultant both in rheology and nanotechnologies. OW developed KK-sensors and the related theory. All the authors read and approved the final manuscript.
  1 in total

1.  The Hamaker constant of anatase aqueous suspensions.

Authors:  A I Gómez-Merino; F J Rubio-Hernández; J F Velázquez-Navarro; F J Galindo-Rosales; P Fortes-Quesada
Journal:  J Colloid Interface Sci       Date:  2007-08-30       Impact factor: 8.128

  1 in total
  2 in total

1.  Rheological Modeling of Metallic Oxide Nanoparticles Containing Non-Newtonian Nanofluids and Potential Investigation of Heat and Mass Flow Characteristics.

Authors:  Muhammad Rizwan; Mohsan Hassan; Oluwole Daniel Makinde; Muhammad Mubashir Bhatti; Marin Marin
Journal:  Nanomaterials (Basel)       Date:  2022-04-06       Impact factor: 5.076

2.  Rheological and volumetric properties of TiO2-ethylene glycol nanofluids.

Authors:  David Cabaleiro; María J Pastoriza-Gallego; Carlos Gracia-Fernández; Manuel M Piñeiro; Luis Lugo
Journal:  Nanoscale Res Lett       Date:  2013-06-13       Impact factor: 4.703

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.