Literature DB >> 21710480

Randomized clinical trial of tissue glue versus absorbable sutures for mesh fixation in local anaesthetic Lichtenstein hernia repair.

H Paajanen1, J Kössi, S Silvasti, T Hulmi, T Hakala.   

Abstract

BACKGROUND: Chronic pain may be a long-term problem related to mesh fixation and operative trauma after Lichtenstein hernioplasty. The aim of this study was to compare the feasibility and safety of tissue cyanoacrylate glue versus absorbable sutures for mesh fixation in Lichtenstein hernioplasty.
METHODS: Lichtenstein hernioplasty was performed under local anaesthesia as a day-case operation in one of three hospitals. The patients were randomized to receive either absorbable polyglycolic acid 3/0 sutures (Dexon(®); 151 hernias) or 1 ml butyl-2-cyanoacrylate tissue glue (Glubran(®); 151 hernias) for fixation of lightweight mesh (Optilene(®)). Wound complications, pain, discomfort and recurrence were identified at 1 and 7 days, 1 month and 1 year after surgery.
RESULTS: A total of 302 patients were included in the study. The mean(s.d.) duration of operation was 34(12) min in the glue group and 36(13) min in the suture group (P = 0·113). The need for analgesics was similar during the first 24 h after surgery. Five wound infections (3·4 per cent) were detected in the glue group and two (1·4 per cent) in the suture group (P = 0·448). The recurrence rate at 1 year was 1·4 per cent in each group (P = 1·000). The rates of foreign body sensation, acute and chronic pain were similar in the two groups. Logistic regression analysis showed that the type of mesh fixation did not predict chronic pain 1 year after surgery.
CONCLUSION: Mesh fixation without sutures in Lichtenstein hernioplasty was feasible without compromising postoperative outcome. REGISTRATION NUMBER: NCT00659542 (http://www.clinicaltrials.gov).
Copyright © 2011 British Journal of Surgery Society Ltd. Published by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21710480     DOI: 10.1002/bjs.7598

Source DB:  PubMed          Journal:  Br J Surg        ISSN: 0007-1323            Impact factor:   6.939


  23 in total

1.  Evaluation of fibrin sealant for biologic mesh fixation at the hiatus in a porcine model.

Authors:  David M Krpata; Jeffrey A Blatnik; Karem C Harth; Melissa S Phillips; Yuri W Novitsky; Michael J Rosen
Journal:  Surg Endosc       Date:  2012-04-27       Impact factor: 4.584

Review 2.  Glue versus suture fixation of mesh during open repair of inguinal hernias: a systematic review and meta-analysis.

Authors:  Hugh Shunsuke Colvin; Ahsan Rao; Marta Cavali; Giampiero Campanelli; Amin Ibrahim Amin
Journal:  World J Surg       Date:  2013-10       Impact factor: 3.352

Review 3.  Use of cyanoacrylate adhesives in general surgery.

Authors:  David García Cerdá; Antonio Martín Ballester; Alicia Aliena-Valero; Anna Carabén-Redaño; José M Lloris
Journal:  Surg Today       Date:  2014-10-25       Impact factor: 2.549

4.  The Fixation on Fixation. IC on: Randomized Clinical Trial Comparing Cyanoacrylate Glue Versus Suture Fixation in Lichtenstein Hernia Repair-7-Year Outcome Analysis.

Authors:  Danny Rosin
Journal:  World J Surg       Date:  2017-01       Impact factor: 3.352

Review 5.  Mesh fixation with glue versus suture for chronic pain and recurrence in Lichtenstein inguinal hernioplasty.

Authors:  Ping Sun; Xiang Cheng; Shichang Deng; Qinggang Hu; Yi Sun; Qichang Zheng
Journal:  Cochrane Database Syst Rev       Date:  2017-02-07

6.  Laparoscopic Versus Open Preperitoneal Mesh Repair of Inguinal Hernia: an Integrated Systematic Review and Meta-analysis of Published Randomized Controlled Trials.

Authors:  Muhammad Shafique Sajid; Jennifer Caswell; Krishna K Singh
Journal:  Indian J Surg       Date:  2015-04-28       Impact factor: 0.656

7.  Host tissue response by the expression of collagen to cyanoacrylate adhesives used in implant fixation for abdominal hernia repair.

Authors:  Gemma Pascual; Marta Rodríguez; Bárbara Pérez-Köhler; Claudia Mesa-Ciller; Mar Fernández-Gutiérrez; Julio San Román; Juan M Bellón
Journal:  J Mater Sci Mater Med       Date:  2017-02-16       Impact factor: 3.896

8.  Randomized Clinical Trial Comparing Cyanoacrylate Glue Versus Suture Fixation in Lichtenstein Hernia Repair: 7-Year Outcome Analysis.

Authors:  M Matikainen; J Kössi; S Silvasti; T Hulmi; H Paajanen
Journal:  World J Surg       Date:  2017-01       Impact factor: 3.352

Review 9.  Uniformity of Chronic Pain Assessment after Inguinal Hernia Repair: A Critical Review of the Literature.

Authors:  Marijke Molegraaf; Johan Lange; Arthur Wijsmuller
Journal:  Eur Surg Res       Date:  2016-08-27       Impact factor: 1.745

10.  Factors predicting chronic pain after open inguinal hernia repair: a regression analysis of randomized trial comparing three different meshes with three fixation methods (FinnMesh Study).

Authors:  M Matikainen; E Aro; J Vironen; J Kössi; T Hulmi; S Silvasti; I Ilves; M Hertsi; K Mustonen; H Paajanen
Journal:  Hernia       Date:  2018-05-04       Impact factor: 4.739

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.