X-ray coherent scattering form factors of tissues, water and plastics using energy dispersion.

B W King1, K A Landheer, P C Johns.   

Abstract

A key requirement for the development of the field of medical x-ray scatter imaging is accurate characterization of the differential scattering cross sections of tissues and phantom materials. The coherent x-ray scattering form factors of five tissues (fat, muscle, liver, kidney, and bone) obtained from butcher shops, four plastics (polyethylene, polystyrene, lexan (polycarbonate), nylon), and water have been measured using an energy-dispersive technique. The energy-dispersive technique has several improvements over traditional diffractometer measurements. Most notably, the form factor is measured on an absolute scale with no need for scaling factors. Form factors are reported in terms of the quantity x = λ(-1)sin (θ/2) over the range 0.363-9.25 nm(-1). The coherent form factors of muscle, liver, and kidney resemble those of water, while fat has a narrower peak at lower x, and bone is more structured. The linear attenuation coefficients of the ten materials have also been measured over the range 30-110 keV and parameterized using the dual-material approach with the basis functions being the linear attenuation coefficients of polymethylmethacrylate and aluminum.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21709341     DOI: 10.1088/0031-9155/56/14/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Application of machine learning classifiers to X-ray diffraction imaging with medically relevant phantoms.

Authors:  Stefan Stryker; Anuj J Kapadia; Joel A Greenberg
Journal:  Med Phys       Date:  2021-12-01       Impact factor: 4.071

2.  X-ray diffraction tomography with limited projection information.

Authors:  Zheyuan Zhu; Alexander Katsevich; Anuj J Kapadia; Joel A Greenberg; Shuo Pang
Journal:  Sci Rep       Date:  2018-01-11       Impact factor: 4.379

3.  Mechanical and Imaging Properties of a Clinical-Grade Kidney Phantom Based on Polydimethylsiloxane and Elastomer.

Authors:  Izdihar Kamal; Hairil Rashmizal Abdul Razak; Muhammad Khalis Abdul Karim; Syamsiah Mashohor; Josephine Ying Chyi Liew; Yiin Jian Low; Nur Atiqah Zaaba; Mazlan Norkhairunnisa; Nur Athirah Syima Mohd Rafi
Journal:  Polymers (Basel)       Date:  2022-01-28       Impact factor: 4.329

4.  Identification of amyloid plaques in the brain using an x-ray photon-counting strip detector.

Authors:  Bahaa Ghammraoui; Aldo Badano
Journal:  PLoS One       Date:  2020-02-11       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.