Literature DB >> 21707268

Comparative study of low- versus high-resolution liquid chromatography-mass spectrometric strategies for measuring perfluorinated contaminants in fish.

H Kadar1, B Veyrand, J-P Antignac, S Durand, F Monteau, B Le Bizec.   

Abstract

Perfluorinated compounds (PFCs) are usually monitored by high-performance liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) on triple quadrupole instruments. Although not yet widely implemented in the field, high-resolution mass spectrometry (HRMS) today appears as a valuable alternative for these halogenated chemicals due to their significant mass defect. Indeed, this second approach offers a way to cope with particular matrix effects caused by co-eluting and isobaric interferences affecting the measurement of some PFCs in fish. The present study compares three different LC-MS-related instruments and various signal acquisition modes, from low-resolution full-scan and selected ion-monitoring (SIM) mode on a triple quadrupole (QqQ) instrument to high-resolution full-scan or product ion-scan mode on orbital trap (LTQ-Orbitrap) or quadrupole-time-of-flight (Q-TOF) devices. Performances are compared for seven model compounds belonging to seven PFCs subclasses: perfluoralkylsulfonate, perfluoroalkylcarboxylate, perfluoroalkylsulfinate, perfluoroalkyl-sulfonamide, fluorotelomer saturated acid, fluorotelomer unsaturated acid and perfluoroalkylphosphonic acid. Low-resolution MS/MS was found to be unsurprisingly reliable for extended multi-residue monitoring. However, the high stability of PFCs leads to a relatively poor and non-specific fragmentation pathway in MS/MS. In addition, biliary acid-interfering compounds (e.g. taurochenodeoxycholic acid), which where encountered in the present case in fish samples but that may be present in other biological samples, were found particularly disturbing in low-resolution MS/MS. Indeed, these interferences presented the same retention time and diagnostic signals as PFOS, leading to a possible overestimation of the PFOS quantification in LC-MS/MS. On the other hand, high-resolution MS and MS/MS (LTQ-Orbitrap and Q-TOF) provided better results in terms of signal specificity and sensitivity. For instance, the estimated limits of detection (LOD) reached for PFOS on QqQ, Q-TOF and LTQ-Orbitrap instruments were 3.8, 0.7 and 0.5 pg injected, respectively.
© 2011 Taylor & Francis

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21707268     DOI: 10.1080/19440049.2011.583283

Source DB:  PubMed          Journal:  Food Addit Contam Part A Chem Anal Control Expo Risk Assess        ISSN: 1944-0057


  1 in total

1.  Assessment of Perfluorooctane Sulfonate and Perfluorooctanoic Acid Exposure Through Fish Consumption in Italy.

Authors:  Andrea Barbarossa; Teresa Gazzotti; Federica Farabegoli; Francesca R Mancini; Elisa Zironi; Luca Busani; Giampiero Pagliuca
Journal:  Ital J Food Saf       Date:  2016-11-02
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.