Literature DB >> 21705569

Metal ion levels in patients with a lumbar metal-on-metal total disc replacement: should we be concerned?

P Bisseling1, D J Zeilstra, A M Hol, J L C van Susante.   

Abstract

The purpose of this study was to evaluate whether concerns about the release of metal ions in metal-on-metal total hip replacements (THR) should be extended to patients with metal-bearing total disc replacements (TDR). Cobalt and chromium levels in whole blood and serum were measured in ten patients with a single-level TDR after a mean follow-up of 34.5 months (13 to 61) using inductively-coupled plasma mass spectrometry. These metal ion levels were compared with pre-operative control levels in 81 patients and with metal ion levels 12 months after metal-on-metal THR (n = 21) and resurfacing hip replacement (n = 36). Flexion-extension radiographs were used to verify movement of the TDR. Cobalt levels in whole blood and serum were significantly lower in the TDR group than in either the THR (p = 0.007) or the resurfacing group (p < 0.001). Both chromium levels were also significantly lower after TDR versus hip resurfacing (p < 0.001), whereas compared with THR this difference was only significant for serum levels (p = 0.008). All metal ion levels in the THR and resurfacing groups were significantly higher than in the control group (p < 0.001). In the TDR group only cobalt in whole blood appeared to be significantly higher (p < 0.001). The median range of movement of the TDR was 15.5° (10° to 22°). These results suggest that there is minimal cause for concern about high metal ion concentrations after TDR, as the levels appear to be only moderately elevated. However, spinal surgeons using a metal-on-metal TDR should still be aware of concerns expressed in the hip replacement literature about toxicity from elevated metal ion levels, and inform their patients appropriately.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21705569     DOI: 10.1302/0301-620X.93B7.26392

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  9 in total

1.  Metallic ion release after knee prosthesis implantation: a prospective study.

Authors:  Adrien Lons; Sophie Putman; Gilles Pasquier; Henri Migaud; Elodie Drumez; Julien Girard
Journal:  Int Orthop       Date:  2017-06-14       Impact factor: 3.075

2.  Prospective study on serum metal levels in patients with metal-on-metal lumbar disc arthroplasty.

Authors:  Matthew F Gornet; J K Burkus; M L Harper; F W Chan; A K Skipor; J J Jacobs
Journal:  Eur Spine J       Date:  2012-11-20       Impact factor: 3.134

3.  We Need to Talk about Lumbar Total Disc Replacement.

Authors:  Stephen Beatty
Journal:  Int J Spine Surg       Date:  2018-08-03

Review 4.  Total Disc Replacement in Lumbar Degenerative Disc Diseases.

Authors:  Chun Kun Park
Journal:  J Korean Neurosurg Soc       Date:  2015-11-30

Review 5.  Metal ion concentrations in body fluids after implantation of hip replacements with metal-on-metal bearing--systematic review of clinical and epidemiological studies.

Authors:  Albrecht Hartmann; Franziska Hannemann; Jörg Lützner; Andreas Seidler; Hans Drexler; Klaus-Peter Günther; Jochen Schmitt
Journal:  PLoS One       Date:  2013-08-07       Impact factor: 3.240

6.  ISASS Policy Statement - Lumbar Artificial Disc.

Authors:  Jack Zigler; Rolando Garcia
Journal:  Int J Spine Surg       Date:  2015-03-12

7.  Serum metal ion concentrations in paediatric patients following total knee arthroplasty using megaprostheses.

Authors:  Jörg Friesenbichler; Patrick Sadoghi; Werner Maurer-Ertl; Joanna Szkandera; Mathias Glehr; Kathrin Ogris; Matthias Wolf; Christian Weger; Andreas Leithner
Journal:  Biomed Res Int       Date:  2014-09-08       Impact factor: 3.411

8.  Total disc replacement versus fusion for lumbar degenerative diseases - a meta-analysis of randomized controlled trials.

Authors:  Deng-Yan Bai; Long Liang; Bing-Bing Zhang; Tao Zhu; Hai-Jun Zhang; Zhi-Guo Yuan; Yan-Fei Chen
Journal:  Medicine (Baltimore)       Date:  2019-07       Impact factor: 1.817

9.  Wear characteristics of an unconstrained lumbar total disc replacement under a range of in vitro test conditions.

Authors:  Philip J Hyde; John Fisher; Richard M Hall
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2015-09-28       Impact factor: 3.368

  9 in total