Literature DB >> 21704530

The effects of skinfold thicknesses and innervation zone on the mechanomyographic signal during cycle ergometry.

Jorge M Zuniga1, Terry J Housh, Clayton L Camic, C Russell Hendrix, Haley C Bergstrom, Richard J Schmidt, Glen O Johnson.   

Abstract

The purpose of this study was to examine the effects of skinfold (SF) thicknesses at four locations on the vastus lateralis (VL) muscle and the placement of accelerometers relative to the innervation zone (IZ) on the mechanomyographic (MMG) amplitude and mean power frequency (MPF) responses during incremental cycle ergometry. Twenty adults (age±SD=23.8±3.0 years) participated in the investigation. The MMG signals were detected during incremental cycle ergometry using four accelerometers placed on the right VL. Prior to the cycle ergometer test, SF thicknesses were measured. Simple linear regression analyses and one-way repeated measures analyses of variance (ANOVAs) were performed. The present study found that only 10% of the regression analyses and mean comparisons were significant (p<0.05). Furthermore, the accelerometer placed at the most proximal site (Prox 2) had significantly greater MMG amplitude and MMG MPF than accelerometers placed at more distal sites (Prox 1, Over IZ, and Dist). There were no significant differences, however, in SF thickness between accelerometer placement sites. In addition, the IZ had no effect on MMG amplitude and little effect on MMG MPF values. The results of the present study indicated that the SF thickness values and IZ did not affect the MMG signal.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21704530     DOI: 10.1016/j.jelekin.2011.05.009

Source DB:  PubMed          Journal:  J Electromyogr Kinesiol        ISSN: 1050-6411            Impact factor:   2.368


  4 in total

1.  Mechanomyographic parameter extraction methods: an appraisal for clinical applications.

Authors:  Morufu Olusola Ibitoye; Nur Azah Hamzaid; Jorge M Zuniga; Nazirah Hasnan; Ahmad Khairi Abdul Wahab
Journal:  Sensors (Basel)       Date:  2014-12-03       Impact factor: 3.576

2.  The Effect of Skinfold on the Assessment of the Mean Power Frequency at the Fatigue Threshold.

Authors:  Alyssandra N Baniqued; Jorge M Zuniga; Thomas C Strunc; Katie M Keenan; Agrini K Boken; Jeffrey J Anderson
Journal:  Int J Exerc Sci       Date:  2016-10-01

3.  Skeletal muscle oxygenation during cycling at different power output and cadence.

Authors:  Lisha Shastri; Mariana Alkhalil; Claire Forbes; Tina El-Wadi; Gerrard Rafferty; Koji Ishida; Federico Formenti
Journal:  Physiol Rep       Date:  2019-02

4.  Association of anthropometric parameters with amplitude and crosstalk of mechanomyographic signals during forearm flexion, pronation and supination torque tasks.

Authors:  Irsa Talib; Kenneth Sundaraj; Chee Kiang Lam
Journal:  Sci Rep       Date:  2019-11-07       Impact factor: 4.379