Literature DB >> 21704485

Assessing short-term functional outcomes and knee alignment of computer-assisted navigated total knee arthroplasty.

M Moin Khan1, M Wahab Khan, Hatem H Al-Harbi, Brad S Weening, Paul K Zalzal.   

Abstract

This retrospective study examined the relationship between the mechanical axis of the knee throughout its functional arc and functional outcomes in patients with computer-assisted navigation total knee arthroplasty. Data on final intraoperative functional arc alignment were obtained on 76 patients who had computer-assisted navigation total knee arthroplasty over a 2-year period and correlated with scores from postoperative Short Form 12 and Western Ontario and McMaster Universities functional outcome surveys. No correlation was found between functional arc alignment and outcomes from Western Ontario and McMaster Universities or Short Form 12 surveys; however, subgroup analysis of patients with more than 3° average final intraoperative alignment throughout the functional arc of motion demonstrated increased difficulty with daily activities (P = .05). The results indicate that patients with more than 3° average alignment throughout the functional arc of motion perform more poorly with daily activities postoperatively.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21704485     DOI: 10.1016/j.arth.2011.04.038

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  8 in total

Review 1.  Computer Assisted Total Knee Arthroplasty: Does it Make a Difference?

Authors:  Emil G Haritinian; Ashvin L Pimpalnerkar
Journal:  Maedica (Buchar)       Date:  2013-06

2.  Inconsistencies between navigation data and radiographs in total knee arthroplasty are system-dependent and affect coronal alignment.

Authors:  Alberto Carli; Ahmed Aoude; Avishai Reuven; Bogdan Matache; John Antoniou; David J Zukor
Journal:  Can J Surg       Date:  2014-10       Impact factor: 2.089

3.  Kinematic alignment in total knee arthroplasty: Does it really matter?

Authors:  Raju Karuppal
Journal:  J Orthop       Date:  2016-11-01

4.  Influence of computer navigation on TKA revision rates.

Authors:  Christoph Schnurr; Isabell Güdden; Peer Eysel; Dietmar Pierre König
Journal:  Int Orthop       Date:  2012-09-05       Impact factor: 3.075

5.  Mechanical, Anatomical, and Kinematic Axis in TKA: Concepts and Practical Applications.

Authors:  Jeffrey J Cherian; Bhaveen H Kapadia; Samik Banerjee; Julio J Jauregui; Kimona Issa; Michael A Mont
Journal:  Curr Rev Musculoskelet Med       Date:  2014-06

6.  Long-term functional outcomes and knee alignment of computer-assisted navigated total knee arthroplasty.

Authors:  V Sardana; J M Burzynski; M Khan; N Stone; B S Weening; P K Zalzal
Journal:  Musculoskelet Surg       Date:  2016-12-03

7.  Can TKA design affect the clinical outcome? Comparison between two guided-motion systems.

Authors:  Raffaele Mugnai; Vitantonio Digennaro; Andrea Ensini; Alberto Leardini; Fabio Catani
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-30       Impact factor: 4.342

Review 8.  Does malalignment affect patient reported outcomes following total knee arthroplasty: a systematic review of the literature.

Authors:  Mohammed Hadi; Tim Barlow; Imran Ahmed; Mark Dunbar; Peter McCulloch; Damian Griffin
Journal:  Springerplus       Date:  2016-07-28
  8 in total