Literature DB >> 21700444

Bi-cell surface plasmon resonance detection of aptamer mediated thrombin capture in serum.

Rinosh Joshua Mani1, Roman G Dye, Timothy A Snider, Shaopeng Wang, Kenneth D Clinkenbeard.   

Abstract

The serine protease coagulation factor thrombin functions primarily in hemostasis, but is also involved in atherosclerosis, thromboembolic disease, cancer and inflammatory disease. Direct measurement of coagulation proteins including thrombin in plasma samples poses a significant challenge because of lack of specific probes and low thrombin concentrations. In addition, high plasma protein concentrations in samples can result in high backgrounds. These challenges were overcome using a bi-cell surface plasmon resonance (SPR) spectrometer with an immobilized thrombin aptamer to measure thrombin in samples passed through a low volume flow cell. For thrombin in Tris-EDTA buffer, the limit of detection (LOD) was 25 nM. Coefficient of variation (CV) for detection of 50 nM was 12.2% and 12.4% for intra and inter-day measurements respectively. This detection was specific for both thrombin aptamer and for thrombin. Using serum samples spiked with thrombin, the LOD was 50 nM with a linear range of detection from 50 nM to 200 nM. However use of serum samples was associated with consistent, low-level background drift. The contributions of nonspecific protein absorption onto the sensor surface and sample flow speed were assessed, and strategies to reduce this background drift were explored. We conclude that the bi-cell SPR platform with an aptamer capture probe can be employed as a highly sensitive real-time, label-free biosensor for the detection of coagulation factors in plasma samples.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21700444     DOI: 10.1016/j.bios.2011.05.049

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

1.  Accelerating Post-SELEX Aptamer Engineering Using Exonuclease Digestion.

Authors:  Juan Canoura; Haixiang Yu; Obtin Alkhamis; Daniel Roncancio; Rifat Farhana; Yi Xiao
Journal:  J Am Chem Soc       Date:  2020-12-30       Impact factor: 15.419

2.  Study of Small-Molecule-Membrane Protein Binding Kinetics with Nanodisc and Charge-Sensitive Optical Detection.

Authors:  Guangzhong Ma; Yan Guan; Shaopeng Wang; Han Xu; Nongjian Tao
Journal:  Anal Chem       Date:  2016-01-25       Impact factor: 6.986

3.  Manipulating the hydrophobicity of DNA as a universal strategy for visual biosensing.

Authors:  Zhong Feng Gao; Rui Liu; Jinhua Wang; Jun Dai; Wei-Hua Huang; Mingjie Liu; Shutao Wang; Fan Xia; Shusheng Zhang; Lei Jiang
Journal:  Nat Protoc       Date:  2020-01-08       Impact factor: 13.491

4.  Demonstration of a Label-Free and Low-Cost Optical Cavity-Based Biosensor Using Streptavidin and C-Reactive Protein.

Authors:  Donggee Rho; Seunghyun Kim
Journal:  Biosensors (Basel)       Date:  2020-12-24

5.  Quantification of Single-Molecule Protein Binding Kinetics in Complex Media with Prism-Coupled Plasmonic Scattering Imaging.

Authors:  Pengfei Zhang; Guangzhong Ma; Zijian Wan; Shaopeng Wang
Journal:  ACS Sens       Date:  2021-03-15       Impact factor: 7.711

6.  In situ targeting TEM8 via immune response and polypeptide recognition by wavelength-modulated surface plasmon resonance biosensor.

Authors:  Yimin Wang; Zewei Luo; Kunping Liu; Jie Wang; Yixiang Duan
Journal:  Sci Rep       Date:  2016-01-29       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.